5
1 Installation
1.1 At
delivery
F2 is delivered in the
transport mode
. This means that only the real
time clock is active. No measurements take place in this position.
The
transport mode
is indicated by a "no" in the upper left hand
corner.
Before installation commences the meter is to be set in the
operating mode
. This is done by pressing and holding the push
button for approximately five seconds, and thus entering one of the
following two modes:
1.
Service mode
: Normally the calculator is set to enter the
service mode
. Here it is possible to alter certain parameters
in the calculator. See also
4. Service
. To indicate that the
meter has left
transport mode
, "no" on the display
extinguishes and is replaced by "00” -
service mode
.
2.
Operating mode
: If so ordered, the F2 calculator is set to
enter the
operating mode
directly. To indicate that the
meter has left
transport mode
, "no" on the display
extinguishes and is replaced by "10” -
operating mode
.
To enter the
service mode
from
operating mode
, please cf.
4. Service.
Note:
In order to complete the installation the integrator must be set to
operating mode
.
Fig. 1.1c,
Operation (normal) mode. The calculator
must be set into this mode in order to measure
YES
Fig. 1.1d, NOT operation mode
Upper display Transport mod
middle display Service mode
Lower display Test mode
NO
Blinking digits
Fig. 1.1a, Transport mode
m³/h
kW
°C
m³
F2
Mad e in Swed en Nr: 000433
Display button
Fig. 1.1b, F2 display button