![METREL AlphaPAT Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/metrel/alphapat/alphapat_instruction-manual_1779011038.webp)
MI 2142 AlphaPAT Autotest modes
38
7.4.4 Substitute leakage current measurement
Notes:
Consider the warnings on the display before starting measurement!
For class II appliances the test probe is used!
The autotest sequence stops when substitute leakage current measurement is
performed. The following actions can be taken to continue or complete autotest
sequence:
F1 key....................... proceed to the next substitute leakage current measurement (in
continuous measurement mode only)
F2 key....................... repeat the substitute leakage current measurement
START key ............... proceed to the next autotest sequence measurement
ESC key.................... end autotest sequence without saving autotest results
7.4.5 Leakage current and apparent power measurement
Notes:
If any of the earth bond resistance, insulation resistance, or substitute leakage
current measurements have failed in autotest sequence, the leakage current
measurement is prohibited!
Consider the displayed warnings before starting or proceeding with
measurements!
The autotest sequence stops after the leakage current measurement is performed. The
following actions can be taken to continue or complete autotest sequence:
F1 key....................... proceed with the next leakage current measurement (in
continuous measurement mode only)
F2 key....................... repeat the leakage current measurement
START key ............... proceed to the next autotest sequence measurement
ESC key.................... end autotest sequence without saving autotest results
7.4.6 Touch leakage current measurement
Notes:
Consider the warnings on the display before starting measurement!
If any of earth bond resistance, insulation resistance, substitute leakage current
or leakage current measurements have failed or were skipped in selected
autotest sequence, the touch leakage current measurement is prohibited!
The autotest sequence stops after performing touch leakage current measurement. The
following actions can be taken to continue or complete autotest sequence:
F1 key....................... proceed to the next touch leakage current measurement (in
continuous measurement mode only)
F2 key....................... repeat the touch leakage current measurement
START key ............... proceed to the next autotest sequence measurement
ESC key.................... end autotest sequence without saving autotest results