IMPORTANT

Please read all of the instructions before installation

MA019168

      

Aroha Shower Mixer

01-9168

Use of this product is recommended for domestic and commercial applications.

All pipework must be thoroughly flushed prior to the installation of the mixer.

Inline filter washers must be installed on both hot and cold supplies to prevent foreign particles 

damaging the ceramic cartridge.

Do not remove the ceramic cartridge from the mixer when installing.

Methven recommends a licensed plumber carry out all installations in compliance with  

the requirements of AS/NZS 3500. This product complies with AS/NZS 3718 regulations.

JUNE 2012

Installation Guide

www.methven.com

Customer Care Hotline: 1300 METHVEN (638 483)

Email: [email protected]

Installation 

1. Screw the body assembly (1) on to the 

mounting stud positioned to observe 
installation depth, ID (to front of finished 
wall lining e.g. tiles) as follows:

  Range of Install Depth, 

ID

 = 42-62 mm

  Note: Two sizes of half dome (5 & 6) are 

supplied.

  Long dome (6) for 42-52 mm
  Short dome (5) for 52-62mm

2. Connect body assembly (1) into system 

and replace body assembly cover.

3. Cut hole in lining as pictured.

4. Wall lining e.g. tiles should be finished as 

close as possible to the plastic template. 
Remove plastic template prior to next 
step.

5. Lubricate the o-ring in the faceplate 

(2). Place faceplate (2) over mixer body 
and slide firmly over the mixer body 
until flat on the wall surface with the 
faceplate’s (2)drain slot at the bottom. It 
is recommended that a bead of silicone 
sealant is applied to the back of the 
faceplate before fixing to the finished wall 
surface.

6. Push inner dome (3) onto cartridge 

spindle, fit o-ring (4) and appropriate half 
dome (5 or 6) over the body assembly (1) 
and align to the form of the faceplate.

  Fit handle (7) and fasten grub screw with 

2.5mm hex key (8).

4.

6.

5.

Finished 
Wall

1.

3.

2.

Hot

Cold

Plastic 
template

ID

ø 50mm

Max cut out in 
wall lining