background image

Methven Australia Pty Ltd

ABN 15 104 813 390

Melbourne, Australia

www.methven.com

Cold

Hot

WMKA21005

IMPORTANT

Please read all of the instructions before installation

MA018123

      

Waipori Wall Mounted  

Mixer with Plate

Basin: 01-8123

Bath: 01-8246

Use of this product is recommended for domestic and commercial applications.

Domestic and commercial warranty terms and conditions vary. Please refer to the Methven website 

for full warranty terms and conditions - www.methven.com

All pipework must be thoroughly flushed prior to the installation of the mixer.

Inline filter washers must be installed on both hot and cold supplies to prevent foreign particles 

damaging the ceramic cartridge.

Do not remove the ceramic cartridge from the mixer when installing.

Damage caused by hydrostatic testing is not covered by Methven’s warranty.

Methven recommends a licensed plumber carry out all installations in compliance with  

the requirements of AS/NZS 3500. This product complies with AS/NZS 3718 regulations.

April 2012

Installation Guide

Ceramic Cartridge

Adjustment

Do not remove the ceramic cartridge
from the body while carrying out the
following adjustments.

Note: the cartridge is factory

set for maximum temperature.

www.methven.com

Customer Care Hotline: 1300 METHVEN (638 483)

Email: [email protected]

5.

Use appropriate Half Dome 

for installation depth.

115mm

Hole cutout

 

Max 22mm

Use Plastic Template as hole 

shape guide as seen in step 4.

Remove half-dome (if attached)

Flow limiting  

adjustment

Mix  

temperature  

limiting  

adjustment

+

+

-

Installation 

1.     Screw the body assembly (1) into the 

mounting stud.

2.  Screw the body assembly (1) on to the  

  mounting stud positioned to observe the  

  installation depth range as follows:

  Range of Install Depth, ID = 54 to 75 mm

  Note: Two sizes of half dome (5 & 6) are  

 supplied:

  Long dome (6) for 54-65 mm

  Short dome for (5) for 65-75 mm
3.   Cut holes in lining as pictured.
4.  Connect brass nipple and ensure a  
  seal with Teflon tape or similar. Trim  
  the brass nipple to 15 +/- 2mm protruding  
  from finished wall lining. Lubricate the  
  o-ring in the faceplate (2). Place the  
  faceplate (2) over the the body assembly  
  (1) until flat on the finished wall surface.  
  Screw the faceplate (2) into the fixing ring  
  using the screws provided (10).
5.  Fit o-ring (7) and appropriate half dome 
  (5) or (6) over the body assembly  
  (1). Fit handle (8) and fasten grub  
  screw with 2.5mm hex key (9). Screw  
  on the brass connector (3) and ensure a seal 
     with Teflon tape or similar.Push spout (4) 
  into place over brass connector (3) and lock 
  into place by tightening with the 2.5mm hex  
  key supplied (9). Place handle onto mixer  
    and fasten grub screw with 2.5mm hex key
   supplied (9).

57mm

60mm

R10mm

Ensure top surface is horizontal

Applies to basin 

mixer only

4.

1.

2.

3.

6.

15mm 

+/-

 2

ID

Note: Do not rotate spout against faceplate to avoid scratching.