Methven Australia Pty Ltd
ABN 15 104 813 390
Melbourne, Australia
www.methven.com
Cold
Hot
WMKA21005
IMPORTANT
Please read all of the instructions before installation
MA018123
Waipori Wall Mounted
Mixer with Plate
Basin: 01-8123
Bath: 01-8246
Use of this product is recommended for domestic and commercial applications.
Domestic and commercial warranty terms and conditions vary. Please refer to the Methven website
for full warranty terms and conditions - www.methven.com
All pipework must be thoroughly flushed prior to the installation of the mixer.
Inline filter washers must be installed on both hot and cold supplies to prevent foreign particles
damaging the ceramic cartridge.
Do not remove the ceramic cartridge from the mixer when installing.
Damage caused by hydrostatic testing is not covered by Methven’s warranty.
Methven recommends a licensed plumber carry out all installations in compliance with
the requirements of AS/NZS 3500. This product complies with AS/NZS 3718 regulations.
April 2012
Installation Guide
Ceramic Cartridge
Adjustment
Do not remove the ceramic cartridge
from the body while carrying out the
following adjustments.
Note: the cartridge is factory
set for maximum temperature.
www.methven.com
Customer Care Hotline: 1300 METHVEN (638 483)
Email: [email protected]
5.
Use appropriate Half Dome
for installation depth.
115mm
Hole cutout
Max 22mm
Use Plastic Template as hole
shape guide as seen in step 4.
Remove half-dome (if attached)
Flow limiting
adjustment
Mix
temperature
limiting
adjustment
+
+
-
Installation
1. Screw the body assembly (1) into the
mounting stud.
2. Screw the body assembly (1) on to the
mounting stud positioned to observe the
installation depth range as follows:
Range of Install Depth, ID = 54 to 75 mm
Note: Two sizes of half dome (5 & 6) are
supplied:
Long dome (6) for 54-65 mm
Short dome for (5) for 65-75 mm
3. Cut holes in lining as pictured.
4. Connect brass nipple and ensure a
seal with Teflon tape or similar. Trim
the brass nipple to 15 +/- 2mm protruding
from finished wall lining. Lubricate the
o-ring in the faceplate (2). Place the
faceplate (2) over the the body assembly
(1) until flat on the finished wall surface.
Screw the faceplate (2) into the fixing ring
using the screws provided (10).
5. Fit o-ring (7) and appropriate half dome
(5) or (6) over the body assembly
(1). Fit handle (8) and fasten grub
screw with 2.5mm hex key (9). Screw
on the brass connector (3) and ensure a seal
with Teflon tape or similar.Push spout (4)
into place over brass connector (3) and lock
into place by tightening with the 2.5mm hex
key supplied (9). Place handle onto mixer
and fasten grub screw with 2.5mm hex key
supplied (9).
57mm
60mm
R10mm
Ensure top surface is horizontal
Applies to basin
mixer only
4.
1.
2.
3.
6.
15mm
+/-
2
ID
Note: Do not rotate spout against faceplate to avoid scratching.