background image

 

 

BLUE’LOG XM / XC  

 

Quick Start Guide 

Version 20180827 

 

 

 

Содержание BLUE LOG XM

Страница 1: ...BLUE LOG XM XC Quick Start Guide Version 20180827...

Страница 2: ...top hat rail latch 10 Network socket RJ45 11 Interface RS485 1 12 Bus termination of 13 Bus termination of 14 Interface RS485 2 15 Voltage output 24 V 500 mA 16 Power supply 24 V 17 Digital inputs 4x...

Страница 3: ...top hat rail Press the device Latch nose extended Closed latch position up WALL INSTALLATION Insert two screws 80 mm apart into the wall Hang the device on the screws using the recesses on the rear s...

Страница 4: ...estricted by using an energy limited circuit A DC source with limited power may also be used The power supply of the blue Log must meet the following requirements Device protection Voltage 24 V DC Cur...

Страница 5: ...web browser e g Chrome Firefox In order to configure it you must first configure the network and set up user access Network configuration The Ethernet connection of the blue Log must be connected to a...

Страница 6: ...ort DNS Netbios http blue xnnnnnnnn No DNS Netbios http blue xnnnnnnnn local n last eight digits of the hardware number The host name can be changed via the web interface in the System Ethernet menu S...

Страница 7: ...te the access meteocontrol is not able to connect to the device in case of service You can change the setting at any time in the menu System User Firmware update and time zone When using the device fo...

Страница 8: ...ware number HW No the blue Log user name and the password Note regarding data protection GDPR At this point we would like to inform you what data we collect when you configure and use the blue Log Use...

Отзывы: