blue’Log X series
13| 52
5.2
Cables and wiring
Recommended cable types for wiring the individual system components are given
below. The restrictions resulting from the wiring are listed as well.
5.2.1
Permitted cable types for the blue’Log power supply
Power cable for supply voltage Voltage range
Cable cross-section
Typ
Fine-stranded cable
U < 24 V DC
1 mm
2
H05V-K
Fine-stranded cable
U >= 24 V DC
0,75 mm
2
H05V-K
5.2.2
Cable types for device connections
Bus cabling (inverters, current sensors)
RS485 data cable (twisted and shielded)
Network cable
Li2YCYv (TP) 2×2×0.5 mm
2
1)
CAT 6
Analog signals (irradiance and temperature sensor)
Sensor cable
LiYCY 2×2×0.5 mm
2
Digital signals (energy meter, remote control and monitoring system)
Telephone cable
J-Y(ST)Y 2×0.6 mm
2
Ethernet network
Network cable
CAT 5 / CAT 6