2 - 1
LWIR
Thermal Imaging Camera
Installation Guide
2.2 Specification Table
Camera Unit
Measurement Range:
0 to 500 °C / 32 to 932 °F
100 to 1000 °C / 212 to 1832 °F
Pixel Resolution:
640 x 480
Pixel Size/ Pitch
17 μm
Spectral Response:
8 to 14 μm
Max Frame Rate: *
60 fps / 7.5 fps
Detector:
640 x 480 Amorphous Silicon
Optic (HFOV x VFOV):
50 ° x 37 °
25 ° x 17 °
Focus Range:
Min 0.3 m to infinity (motorised focus)
Accuracy:
2 °C or 1 .5 % °C of reading
NETD:
40 mk (@ 20 °C) (-20 to 120 °C) 7.5 Hz
Dimensions:
80 x 80 x 222 mm (max) / 3.14 x 3.14 x 8.7 in
(including lens)
Power Rating:
12 to 24 V DC, +/-10% 12 W / IEEE 802.3 at PoE+
Weight:
1.6 kg / 3.5lb
Ambient Temperature:
-20 to 60 °C (-4 to 140 °F)
0 to 95 % humidity (non-condensing)
Environmental Rating:
IP65 / NEMA 4
Compliance
EMC (EN 61326-1)
Camera Supply and I/O
Digital Connections:
M12 X coded 8-way connector: 10/100/1000 Ethernet & IEEE
802.3 at PoE+
Analog Connections:
8-pin Binder Connector: 2 pins - 12-24V DC Power Input
6 pin Functions can be assigned to internal image processing
algorithms
1 x 4 to 20 mA output
1 x 4 to 20 mA output OR relay output
1 x 4 to 20 mA input OR Digital Input OR relay output
Camera Web Browser for alignment & internal image
processing analog I/O setup
Signal-LED:
Visible on rear of camera only (not with jacket) 3 x LED
- Power / Status, Ethernet Comms & Camera internal
temperature
Service:
Water, instrument air for optional cooling enclosures
SMART Functionalities
Integrated Web Server:
Remote access via Gbit Ethernet interface
Integrated Web Server provides live thermal image
Autonomous Operation:
3 ROIs and configuration of integrated I/Os for full
autonomous operation
Continued...