background image

Metcal is an OK International Company      

Copyright 

©

1999, Metcal, Inc. All Rights Reserved  7036-0540 Rev. A

METCAL QX2 CONVECTION REWORK SYSTEM USER GUIDE

 

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 

Содержание QX2

Страница 1: ...national Company Copyright 1999 Metcal Inc All Rights Reserved 7036 0540 Rev A METCAL QX2 CONVECTION REWORK SYSTEM USER GUIDE Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 Te...

Страница 2: ...P MODE CALIBRATION 8 BOARD HOLDER OVERVIEW SET UP OPERATION 9 PREHEATER OVERVIEW SET UP OPERATION 10 VACUUM CUP ATTACHMENT REMOVAL MAINTENANCE 11 NOZZLE ATTACHMENT REMOVAL 12 FOCUSED CONVECTION NOZZLE...

Страница 3: ...vacuum and heat It has a movable arm that holds the heater head assembly which contains the heating element and the vacuum pick up Because no additional tool stand or work frame is needed the QX2 save...

Страница 4: ...ing the QX2 in places where there are combustible materials Never use the system in the presence of an explosive atmosphere Be aware of your surroundings heat may be transferred to materials which are...

Страница 5: ...ng from the flutes of the nozzle andthetimercountingup WARNING The nozzle and the exhausted air will be hot If you have a preheater that is properly connected to the power supply the preheater will st...

Страница 6: ...roller display the temperature from the auxiliary thermocouple port New Code Allows you to change the Access Code used to enter the Set Up mode Use to change the code Calibrate Allows you to enter the...

Страница 7: ...while minimizing the possibility of warping the PCB SET UP Plug the phone style cable into the jack on the bottom of the preheater Place the preheater on a suitable workbench and stretch out the powe...

Страница 8: ...the heater head WARNING The nozzle may be hot Copyright 1999 Metcal Inc All Rights Reserved 7036 0541 Rev A 13 FOCUSED CONVECTION NOZZLES Nozzle P N Component Type NZ Q11 PLCC 20 NZ Q13 PLCC 28 NZ Q1...

Страница 9: ...t Metcal Customer Care Same as above except it Vacuum cup is too cold and Hold the top of the vacuum tube for at least five mainly occurs when the therefore too stiff to hold seconds until the vacuum...

Страница 10: ...odified repaired altered misused or damaged unit RETURN PROCEDURE Call Metcal at 44 1703 489100 to obtain a returned material authorization RMA number Proof and date of purchase must be on file for th...