Programming—IFC-1010/2020 Programming
29
Table 4: Extended Local Mode Categories and Software Type IDs
1
2
3
4
5
6
7
8
9
A
B
PHOT
MTRB
SPSU
WAT
CON
TPND
TELE
APND
WFS
SSC
PWRC
ION
MPAG
SUPR
SPKR
GPND
PAGE
EVGA
WFC
THER
NOA
FORC
GTC
GAS
MON
SARM
CMXS
TRS
GAC
PULL
SSYM
CMXC
TRC
FTHR
SACM
FRCM
DACT
WAT
SEQM
SCON
Category
Description
NONA
1
If any of the participating standard initiating devices in Category 1 become active, then at
a minimum, all participating standard control/notification devices in Category 5 are
activated (other standard control/notification devices may activate as a side effect of
standard initiating device activation.)
FPHT
2
These initiating devices are never acted on by Local mode and have no side effects for
other devices.
MPUL
3
If these initiating devices become active, Type ID SSC activate.
IOND
4
If these initiating devices become active, Type IDs WFS and WFC activate.
IONH
5
If any of the participating standard initiating devices in Category 1 become active, then all
participating standard control/notification devices in Category 5 become active.
IONL
6
During Local mode these standard control/notification devices are always active.
CMBO
7
These standard control/notification devices activate if they participate in Local mode.
8
These standard control/notification devices activate if any participating or nonparticipating
alarm input is active.
9
These standard control/notification devices activate if any initiating module with Type ID
WAT is active.
A
These standard control/notification devices activate if any initiating module with Type ID
SPSU or SUPR is active.
B
These devices deactivate temporarily upon system reset to remove power to conventional
devices allowing them to reset.
NFPA Listing allows the programmer to change the operation of the panel
based on the NFPA Listings selected. Each listing automatically programs
one or more mandatory modules.
Table 5: NFPA Listings
N17
Listing
Software ID
Address
NFPA 72-1993 (72A) Local Fire Alarm Systems *
EVGA
L1M96
NFPA 72-1993 (72B) Auxiliary Fire Alarm Systems
GAS
L1M97
NFPA 72-1993 (72C) Remote Station Fire Alarm Systems **
GAC
GAC
L1M98
L1M99
NFPA 72-1993 (72D) Proprietary Fire Alarm Systems **
N/A
N/A
NFPA 72-1993 (71) Central Station Fire Alarm Systems **
N/A
N/A
Receiving Unit (RCV) and Central Station Unit
N/A
N/A
* Fire alarm input devices automatically default to latching operation when the 72A Listing is selected.
** NFPA 72-1993(72C), (72D), and (71) are no longer required and should not be selected during programming.