Messtechnik dAV-TRX Скачать руководство пользователя страница 18

revision 1.0

Intercom

Operating Instructions

Charge the batteries before use if you have not used them for a longer period (self discharge of the NiMH 
batteries) and after use.

To avoid capacity loss due to the memory effect, discharge the batteries completely every 5 charging cycles. To 
do this, leave the device on, until it turns off by itself. Then start the charging process as described above.

§

Risk Through High Voltage at the Charging Device

The charger works with mains voltage.

Security references for work with mains voltage must be followed.

!

Warning of Reduced Capacity and Life Span of the Batteries due to Maloperation

Use only the intended chargers from mk messtechnik GmbH.
Powered devices must never be used with a connected charger, e.g. for buffering an empty 

battery.
Disregard can lead to a loss of capacity and a shortened life span of the battery in a short time.

9.3 Charging the Batteries (Battery Pack or Integrated into the Device)

Start of the Charging Process

Place the battery pack or the device to charge onto a stable and skidproof surface.

Turn off the device (see appropriate chapter for operation and operating controls). 

Connect the charger with the battery pack or the device using the designated screw connector (see 

appropriate chapter for operating elements).

Plug the power cord of the charger into the power socket.

Do not power on the device during charging, this can damage the device.

Check the status of the charging LED periodically (the meaning of the states are printed onto the housing of the 
charger).

End of the Charging Process, after the Charging LED Displays the Status “Full”

Make sure that the device to charge is still turned off.

Remove the connection between the charger and the screw connectors of the battery pack or the device to 
charge.

Remove the power plug of the charger from the socket.

The device or battery pack is now ready for operation.

Page 18 / 23

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

 

Содержание dAV-TRX

Страница 1: ...Intercom dAV TRX Manual Intercom system with digital optical transmission Distributed by Reliant EMC LLC 3311 Lewis Ave Signal Hill CA 90755 408 916 5750 www reliantemc com...

Страница 2: ...technik Gmb Contact Distrubuted by Reliant EMC 3311 Lewis Ave Signal Hill CA 90755 Tel 1 408 916 5750 contact reliantemc com www reliantemc com WEEE Reg No DE 21806070 Operating Instructions revision...

Страница 3: ...7 7 Back Side of the Console Device 11 7 8 Front Side of the Secondary Mic 12 7 9 Back Side of the Secondary Mic 13 7 10 Initial Operation 14 8 Operation 15 8 1 Start Stop talking 15 8 2 Volume Contr...

Страница 4: ...sceiver 21 12 1 1 1 Mobile Device 21 12 1 1 2 Console Device 21 12 1 2 Secondary Mic 21 12 2 Charger 22 12 3 Battery Pack 22 13 Accessories Spare parts 23 Page 4 23 Distributed by Reliant EMC LLC 3311...

Страница 5: ...ation The Intercom system is used for optical transmission of audio signals speech 3 Properties The system is suited for the undisturbed isolated transmission of audio signals in surroundings with hig...

Страница 6: ...damaged housing or damaged cables at the charger have to be reported to the responsible expert immediately The affected device has to be decommissioned by the responsible expert and must be protected...

Страница 7: ...the devices only on skid proof surfaces respect the specific installation references for each device Electrical connections are only allowed to be done by authorized EMC trained specialist staff Cons...

Страница 8: ...apture audio signals Integrated microphone Mic On Off On Switch to On to activate permanent talking switch to Off to deactivate permanent talking push to On and hold to talk temporary release from On...

Страница 9: ...Charge DC In Optical In Sig Detect Optical Out PC Figure 7 1 back side of mobile device Sig Detect Permanently on when light is received via the optical link permanently off when no light is received...

Страница 10: ...me In Info Power Volume In PTT Mic 1 Mic 2 Figure 7 3 front side of console device with 2 channels Page 10 23 Figure 7 2 front side of console device dAV TRX Info Volume Out PTT Power Volume In Line I...

Страница 11: ...ng temporary Push button Line In Mic optional Switch to Line In to activate transmission of line in signal switch to Mic to activate transmission of mic signal Switch button Volume In Turn right to in...

Страница 12: ...Switch button Line Out optional Output for line signal received via optical link Socket Cinch Line In optional Input for line signal transmitted via optical link Socket Cinch Audio Out optional Outpu...

Страница 13: ...pture audio signals 3 pole socket XLR connector PTT Push to talk Push and release 250ms to activate deactivate permanent talking push and hold 250ms to talk temporary release to stop talking temporary...

Страница 14: ...the speaker volume If necessary turn the Volume In knob on console device to adjust the mic gain Switch the Mic button to On on mobile device to start talking Power LED blinks Turn the Volume Out kno...

Страница 15: ...button in this position The button switches automatically back to Off when you release it Only one station can talk at a time A blinking power LED indicates that talking is active Example The Mic butt...

Страница 16: ...le device at a time A blinking power PTT LED indicates that talking is active Example The console device is set to permanent talking If the PTT button of the secondary mic is pushed the mic of the con...

Страница 17: ...tions and References Protect the batteries from heat e g long exposure to direct sunlight and fire Do not immerse the batteries into fluids Otherwise there is a risk of explosions Risk of Damage and E...

Страница 18: ...teries Battery Pack or Integrated into the Device Start of the Charging Process Place the battery pack or the device to charge onto a stable and skidproof surface Turn off the device see appropriate c...

Страница 19: ...k GmbH at no cost 10 2 Disposal of Batteries Due to their natural capacity loss batteries must be replaced after their lifespan NEVER open devices or housings by yourself Replacement of batteries must...

Страница 20: ...125 m Batteries empty Charge batteries Other device turned off Turn on other device No transmission white noise or silence at the output Device does not receive an optical signal Check fiber optic ca...

Страница 21: ...rs upon request Mounting plate with 1 4 thread W x H x D Approx 35 mm x 5 mm x 37 mm Microphone Internal mono single ended 12 1 1 2 Console Device Power supply Shielded power supply 110 V to 230 V for...

Страница 22: ...m with 5 pole screw connector Binder 712 series suitable for systems from mk messtechnik GmbH Temperature of operation 0 40 C at maximum load Temperature of storage 40 70 C Protection class IP 40 Ins...

Страница 23: ...e parts For an overview of available accessories please visit www mk messtechnik com For spare parts orders and repairs please contact mk messtechnik GmbH Page 23 23 Distributed by Reliant EMC LLC 331...

Отзывы: