background image

©MESSRING GmbH 
Robert-Stirling-Ring 1 I 82152 Krailling, Germany 

www.messring.de

 

All rights reserved. 
19.09.2018  

1 / 4 

M=BUS Uninterruptible Power Supply (UPS) 

Shockproof rechargeable battery for the M=BUS 
data acquisition system.  

Battery and loop-through operation 

Status LEDs for power level, status and 
charging 

Space saving installation of M=BUS Pro 
devices on top of the UPS 

Passive cell balancing 

TECHNICAL SPECIFICATIONS 

Capacity 

3,500 mAh, 37 VDC (Lithium-Polymer) 

Input voltage (battery charging without consumer) 

9…

36 VDC 

Input voltage (loop-through mode) 

18…

36 VDC 

Max. input power consumption (charging without 
consumer) 

50 W 

Output voltage 

22 VDC 

Max. output power consumption (battery mode) 

154 W 

Max. output power consumption (loop-through mode) 

44 W 

Max. overvoltage protection (input / output) 

60 VDC 

Short circuit protection 

Yes 

Dimensions incl. base plate (L x W x H) 

220 mm x 170 mm x 93 mm 

Weight incl. base plate 

2,646 g 

Operating temperature 

0…35°C

 

Overtemperature protection (shutdown) 

60°C (internal) 

Automatic shutdown 

After 2 min, output power consumption <140 mA 

Shockproof 

100 G 

Отзывы: