Backlite Off
The fluorescent light behind the screen can be turned off if the touch screen is not used,
just like a screen saver on a PC. Set the turn-off time here. A value of 0 will keep the
back light on forever.
Displayed FR
Dampening factor for the
Rate:
indication in the Batch Statistics screen. Increase this
number if the indication is too unstable to be useful.
Loss Slots
The Rate is calculated by taking the difference between two weight values and divide by
the time difference.
Loss Slots
in the number of samples that separates the two values.
Setpoint Slots
If you are using an analog input for the Batch Setpoint, you may have to average (low
pass filter) setpoint samples to get a reliable setpoint value. Increase this number if the
setpoint value in the main screen is noisy.
Date/Time Settings
You can adjust the date and time settings here, in 24 hour format.
Parameter Min
Max
Year 0
99
Month 1
12
Day 1
31
Hour 0
23
Minute 0
59
Seconds 0
59
INPUTS AND OUTPUTS MENU
The I/O system is comprehensive and highly configurable. You reach all the settings and
configuration options from this menu.
Inputs and Outputs Menu
Analog Inputs Setup
The analog inputs can be used for (mapped to) Analog Setpoint or Panel Meter. Two
analog inputs are available when there are two PCIO boards installed. Once the inputs
are mapped, you should adjust the high, low and scaling values.