Содержание CONDENSATOR

Страница 1: ...TION MAINTENANCE TROUBLESHOOTING GUIDELINES Mermaid Manufacturing of Southwest Florida Inc 2651 Park Windsor Drive Suite 203 Fort Myers Fl 33901 Phone 800 330 3553 Fax 239 418 0538 E mail info mmair com Web Site http www mmair com ...

Страница 2: ...ing Guideline 2 TOOLS REQUIRED A Pocket Knife B Flat Blade Screwdriver C Phillips Screwdriver 3 INSTALLATION INSTRUCTIONS WARNING THIS CONDENSATOR MUST BE INSTALLED ABOVE THE WATER LINE OR FLOODING MAY OCCUR First review the contents of the Mermaid Condensator kit insuring you recognize all the parts We suggest you read the complete installation instructions before you start The next thing to do i...

Страница 3: ...itioner and the thru hull water discharge B On the body of the Condensator you will note an arrow This arrow designates the water flow direction thru the Condensator Water flow must be towards the thru hull discharge Slide two of the large stainless steel hose clamps onto each side of the cut hose ends The Condensator will not work if installed with the arrow in the direction back to the air condi...

Страница 4: ...y checking and cleaning your water strainer the inline filter between your Condensator and the condensation pan and the air filter attached to the front of your air conditioning unit From time to time it is possible for the Condensator to cease functioning When this happens your condensation pan may overflow and water may enter your boat This is not necessarily the fault of the Condensator but rat...

Страница 5: ...ect the two ends of the 5 8 water out lines together This is for safety purposes so that water will not leak into the boat while the condensator is being cleaned If you do not have a hose to hose barb insure that the hose ends are placed or tied so that water will not leak out Now look down the hose barb on the Condensator and visually check for any blockage If a blockage is detected clear the obs...

Страница 6: ...u have opened the seacock then turn the air conditioner circuit breaker on and set your thermostat so the air conditioner will turn on Verify that the Condensator is working properly that you have reassembled the check valve assembly correctly and that the Condensator is not allowing water to backflow to the condensation pan Go to your daytimer or calendar and go forward and mark the point where y...

Страница 7: ...the condensation from the air conditioner s condensation tray to the container in the bilge Draw from the container with the Condensator rather than from the air conditioner s condensation tray Seal the two hoses through the top of the container and mount the container in such a way that it won t move in the bilge The condensator works off the flow of water through the air conditioner When the air...