BATTERY BACKUP UNIT

Model E475M-12V

1. Installation instructions for mounting the BBU. 

  After the opener has been installed, position the BBU next

  to the opener on a structural support (joist) within BBU’s

  cord length.

  Attach the BBU to the support by using the wall or ceiling 

  mount holes on either side of the BBU and the 1” (25mm)

  screws (provided).

2. Connect the BBU to the Opener (MR850EVO).

  Disconnect the opener from the electrical outlet.

  Connect the BBU cord into the connector on the bottom of

   the opener (see picture below). Connect the opener into

   the electrical outlet. 

  Turn the power ON. After 2 seconds the Courtesy LEDs will 

  flash 5 times.

  After 20 seconds, the green diagnostic LED (see picture next

  page) will begin to flash indicating the BBU is charging.

IMPORTANT NOTE: 

Installation of the BBU when permanent

electrical power is not available (such as a new construction 

and the electricity is not installed) may damage the battery.

Unplug the BBU after testing to prevent damage.

OPERATING INSTRUCTIONS

1. Test the installed BBU with the opener.

To test the BBU, disconnect the opener power cord from the

electrical power outlet.

  A solid orange LED indicates the BBU is operating on battery 

  power.

  A flashing orange LED indicates the BBU is operating on

  battery power and that the battery charge is low.

  To test the BBU is functioning properly, open and close the

  garage door.

  Re-connect the opener power cord back into the electrical

  outlet.

  Verify that the green LED is flashing on the opener (indicates 

  that the BBU is now charging).

  Test completed.

2. Charge the battery.

  Allow the battery 24 to 48 hours to fully charge before using

  the BBU system.

A fully charged BBU supplies 12V DC to the opener for one

to two days of normal operation during an electrical power

outage.  If the battery voltage drops too low, the battery will

disconnect and the opener will no longer operate under

battery power.

After the electrical power has been restored, the battery will

recharge within 48 hours. Under normal usage the battery

will last 3 to 5 years.

To obtain maximum battery life and prevent damage, 

disconnect the battery backup when the opener is not in

use for an extended period of time.

NOTE:

 Door operation may be limited until the battery is fully

charged.

To prevent possible SERIOUS INJURY or DEATH from

electrocution, disconnect  ALL electric and battery power 

BEFORE performing ANY service or maintenance.

WARNING

OWNERS’S MANUAL

• 

• 

• 

• 

• 

• 

• 

• 

• 

• 

• 

Battery Backup 

Unit (BBU)

• 

MR850EVO