11
Without a properly installed safety reversal
system, persons (particularly small
children) could be SERIOUSLY INJURED or
KILLED by a closing door.
• Incorrect adjustment of garage door travel limits
will interfere with proper operation of safety
reversal system.
• NEVER use force adjustments to compensate for a
binding or sticking garage door.
• After ANY adjustments are made, the safety
reversal system MUST be tested. Door MUST
reverse on contact with 40 mm high object laid flat
on floo
r.
To prevent damage to vehicles, be sure fully open
door provides adequate clearance.
Indicator LED
Indicator LED
figure 2
figure 3
Indicator LED
figure 4
Indicator LED
figure 5
Travel limits regulate the points at which the door will stop
when moving UP or DOWN. The travel limit buttons are located
under the access cover on the rear panel (figure 1).
NOTE: This opener uses a POSITION TAB attached to the chain
which activates a mechanical passpoint during the door travel.
The indicator LED will blink when this occurs. If the passpoint
is not activated during the door travel process, the travel limits
cannot be programmed.
TO PROGRAM THE TRAVEL LIMITS:
1. Press the
PROG
Button until the
UP
Arrow Button and indicator
LED begin to flash (figure 2).
2. Press and hold the
UP
Arrow Button until the door is in the
desired UP position (figure 3).
NOTE: The UP and DOWN Arrow Buttons can be used to move
the door up and down as needed.
3. Once the door is in the desired UP position press and release the
PROG
Button. The
DOWN
Arrow Button will begin to flash (figure
4).
4. Press and hold the
DOWN
Arrow Button until the door is in the
desired DOWN position (figure 5).
NOTE: The UP and DOWN Arrow Buttons can be used to move
the door up and down as needed.
5. Once the door is in the desired DOWN position press and release
the
PROG
Button. The
UP
Arrow Button will begin to flash (figure
2).
SETTING THE FORCE (AUTO):
6. Press and release the
UP
Arrow Button to test the UP limit. When
the door has travelled to the programmed UP limit, the
DOWN
Arrow Button will begin to flash.
7. Press and release the
DOWN
Arrow Button to test the DOWN
limit. The door will travel to the programmed DOWN limit.
The indicator LED will stop flashing. The travel limits and force
setting has now been set. Proceed to test safety reverse system.
SETTING THE FORCE (MANUAL LEARN IF REQUIRED):
1. Open the rear access panel. Locate the yellow Learn button.
2. Push the yellow Learn button twice to enter unit into force
adjustment mode. The LED (indicator light) will flash quickly.
3. Push the programmed remote control or push the
UP/DOWN
arrow at the programming display bar. The door will travel to the
DOWN (close) position. Push the remote control again, the door
will travel to the UP (open) position.
4. Press and release the
DOWN
Arrow Button to test the DOWN
limit. The door will travel to the programmed DOWN limit.
The LED (indicator light) will stop flashing when the force has
been set. The door must travel through a complete cycle, UP
and DOWN, in order for the force to be set properly. If the unit
cannot open and close your door fully, inspect your door to insure
that it is not sticking or binding.
The Force Setting has now been set manually.
PROGRAM THE TRAVEL LIMITS AND FORCE SETTINGS
figure 1
ADJUSTMENT SECTION
19
“The Protector System
TM
” must be used for
all installations where the closing force as
measured on the bottom of the door is over
400 N (40 kgf).
Installers should ensure that the doors are installed
in a compliant manner as per AS/NZS 60335-2-95.