![Meritor MM-0861 Скачать руководство пользователя страница 101](http://html.mh-extra.com/html/meritor/mm-0861/mm-0861_maintenance-manual_1774382101.webp)
Copyright Meritor, Inc., 2022
MM-0861 / Revised 06-22
Page 99
Printed in USA
11 Lubrication and Maintenance
MTC-4208X/XP, MTC-4210X/XP, AND MTC-4213X
4006338f
OIL COOLER READY
INLET
TUBE
FITTINGS
DRAIN
PLUG
FILL
PLUG
FRONT VIEW
FRONT INPUT
YOKE
FRONT
OUTPUT
YOKE
Figure 11.4
CAUTION
Only install the Meritor multi-lip unidirectional seal at the input
position from the transmission in an MTC-4208, MTC-4210, or
MTC-4213 Series transfer case. If the multi-lip seal is installed in
either the rear output position or forward output position on these
transfer cases, loss of lubricant and damage to components can
occur.
The multiple-lip seal must be serviced with the seal and sleeve.
The service part number provides both when required. Check the
application carefully before installing the multiple-lip seal.
Oil Fill Procedure
CAUTION
Only use new lubricant when changing or adjusting the oil in the
transfer case. NEVER reuse lubricant, which can contain metallic
particles and other contaminants. Damage to components can
result.
CAUTION
Meritor does not approve petroleum-based and multi-viscosity oil.
NEVER install API GL-5 oils, which contain extreme-pressure (EP)
additives. These additives can form sludge at normal operating
temperatures. Damage to components can result. Use only SAE
Grade full-synthetic 40W or 50W oil, Meritor specification O-81,
in the transfer case.
CAUTION
When servicing the transfer case, add the specified lubricant until
the oil level is even with the bottom of the fill hole. NEVER overfill
the transfer case, which can cause the transfer case to overheat.
Damage to components can result.
CAUTION
NEVER operate the transfer case if the oil level is below the bottom
of the fill hole, which may be an indication that the transfer case is
leaking. Damage to components can result. If the transfer case is
leaking, repair the leak. Adjust the oil level before returning the
transfer case to service.
NOTE:
Meritor recommends the oil cooler lines should be routed
to prevent oil flow back into the transfer case sump. This can be
accomplished by routing lines with a P-trap configuration for both
the oil cooler inlet and outlet lines. Failure to do so may result
in the oil draining back in to the transfer case sump, giving the
appearance of an over filled transfer case when checking and
adjusting the oil level.
ALTERNATE FILL LOCATION /
BREATHER
OIL FILL
OIL
DRAIN
MAGNETIC
PLUGS
4018584a
Figure 11.5