COD100B/SD102P 

Carbon Monoxide and Smoke 

Alarm Set 

Item ref: 350.137UK 

User Manual 

 

A home safety alarm set consisting of one SD102P photoelectric smoke detector with hush button and one 

COD100B carbon monoxide detector. An essential kit for any home, these life saving devices alert the user 
to the presence of deadly carbon monoxide gas or smoke from a potential fire. 

 

COD100B Product Specifications: 

 

Apparatus 

Type B 

Batteries 

3 x AA (supplied) 

Alarm level 

85dB @ 1m 

Sensor 

Electromechanical 

Static working current 

80uA 

Operating temperature 

0°C to 45°C 

Storage temperature 

-20ºC to 50ºC 

Humidity 

0 to 90% RH 

Lifetime 

7 years from first use 

Dimensions 

120 x 87 x 40mm 

Weight 

220g (incl. batteries) 

 

Product layout: 

 

 

1.

 

Power LED indicator 

2.

 

Fault LED indicator 

3.

 

Alarm LED indicator 

4.

 

LCD display 

5.

 

Alarm output 

6.

 

Test/Menu button 

7.

 

Back cover catch 

8.

 

Battery compartment

Содержание SD102P

Страница 1: ...de gas or smoke from a potential fire COD100B Product Specifications Apparatus Type B Batteries 3 x AA supplied Alarm level 85dB 1m Sensor Electromechanical Static working current 80uA Operating tempe...

Страница 2: ...s rooms with a boiler fireplace or gas oven For optimum detection the alarm needs to be installed at least 1 5m above the ground 0 3m below the ceiling and 1 5m from the corner of the room DO NOT loca...

Страница 3: ...hen the power LED flashes This indicates the battery power is insufficient please replace battery as soon as possible On the LCD display the battery status is also shown constantly Indicates batteries...

Страница 4: ...the concentration of the carbon monoxide reaches above 550ppm the alarm will sound continuously with the LCD displaying Hco high carbon monoxide as below This indicates a dangerously high concentrati...

Страница 5: ...ays remove alarm from the bracket before painting and wait for paint to be fully dry before reinstalling the alarm Avoid shock or impact on the alarm if accidentally dropped check if the battery conne...

Страница 6: ...ows to allow fresh air to flow in and evacuate all persons from room or building Seek medical support immediately Contact the emergency gas service and allow them to inspect the building to ensure it...

Страница 7: ...3 Align the 2 locating slots in the smoke detector with the 2 tags on the installation panel and rotate it clockwise until it locks into position Testing and usage 1 Turn the smoke detector anti clock...

Страница 8: ...qualified personnel Please retain this manual for future reference Intended for Fire Safety and installed in buildings Essential characteristic 1 Pass 13 Essential characteristic 2 Pass 1134 Essential...

Отзывы: