HARDWARE: CIG005A3
SOFTWARE: 1.0.3 o POSTERIOR
GV.1.3.5

Compact 

emergency

phone

MMk-656 

(OPTIONAL)

 

RS-232*
RS-485*
CAN BUS 1*
CAN BUS 2*
GPOS
FXS (connection to phone)
Power supply
OFF/ON Switch
Antenna
Status indicator 
Battery indicator
Coverage indicator 
Autoconfiguration button
 

*Aviable depending on model 

1

2A

2B

3

4

5

6

7

8

9

10

11

12

 

Power supply
MMk-108 
for GSM/M2M
Gateway
(SUPPLIED) 

5

4

3

2

1

7

6

8

9

+

-

OFF/ON

6,2 mm

Negativo -
Po

1,9 mm

TIP
RING

AUX OUT 12Vdc

AUX OUT Colector NPN

OMLS 12Vdc

OMSL Colector NPN - Out Mobile Signal
CAN2 H

CAN2 L

CAN2_GND
CAN1 H

CAN1 L

CAN1_GND
RS485 B

RS485 A

RS485_GND

Modelo 736F

TX

CTS

RX

RTS

GND

RS232C Pines

SMA Antena

Tarjeta SIM

         

CAR

MACHINE

ROOM 

GSM/M2M GATEWAY   MMk-736F / MMk-736N

QUICK SETUP GUIDE

PREPARING THE SIM CARD

1) 

For the following settings, previously introduce the SIM card in a free mobile phone or a mobile telephone 

phone from the SIM card provider.

2)

 Check that the PIN access code of the SIM card is disabled through the security configuration.

3)

 Disable all call forwarding and voicemail line: type 

##002#

, after a few seconds, the operator will confirm 

the cancellation with a message on the screen.

INSTALLATION AND STARTUP

1) 

Introduce the SIM and connect the supplied external antenna to the device

2) 

Connect the emergency phone to the port FXS.

3) 

For remote monitoring (Model MMk-736F), connect the lift controller to the corresponding

4) 

Connect the power supply to the supplied power adapter (12VDC IN).

5) 

Turn on the device (OFF/ON).

WARNING:

 MERak recommends using the supplied antenna and power adapter. Using an unapproved 

by MERak antennas or power adapters may affect the correct performance of the device.
Is important to look for a location for the antenna that provides the best level of coverage: this ensures 

the maximum audio quality while performing voice calls.
To guarantee that enought charge is available to make an emergency call in power failure situations, 

the battery must be completely charged in it’s first use.

Standard telephone landline generator and remote monitoring for lifts

communications port (RS232, RS485, CAN1, CAN2).

WIRING