English
15
Care and service
DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
Dust extraction machines are safety devices for the pre-
vention or elimination of hazards according to the Ger-
man DGUV regulation 1 (German accident prevention
regulation, principles of prevention).
ATTENTION
Care agents containing silicone
These can attach plastic components.
Do not use care agents containing silicone for cleaning.
●
You can perform basic maintenance and care work
yourself.
●
Clean the surface of the device and the interior of
the container regularly with a moist cloth.
Main filter element
Replacing the flat fold filter
1. Open the filter cover.
2. Remove the filter frame.
Illustration N
3. Remove the flat fold filter.
4. Dispose of the used flat fold filter in accordance with
statutory regulations.
5. Remove any dirt deposits from the clean air side.
6. Clean the filter frame and the supporting surface of
the filter frame with a damp cloth.
7. Fit the new flat fold filter. During insertion, ensure
that the flat fold filter is flush on all sides.
8. Insert the filter frame.
9. Close the filter cover until it audibly latches into
place.
Change the candle filter
1. Open the filter cover.
2. Take out the candle filter (special accessories).
Illustration O
3. Dispose of the used candle filter (special accesso-
ries) in accordance with statutory regulations.
4. Remove any dirt deposits from the clean air side.
5. Clean the candle filter frame with a damp cloth.
6. Insert the new candle filter (special accessories).
7. Close the filter cover until it audibly latches into
place.
Changing the fleece filter bag
1. Unlock and remove the suction head.
2. Pull the fleece filter bag out to the rear.
Illustration F
3. Fold in the lock latch and seal the fleece filter bag
tight.
4. Dispose of the used fleece filter bag in accordance
with statutory regulations.
5. Fit the new fleece filter bag.
6. Fit and lock the suction head.
Changing the dust bag
1. Unlock and remove the suction head.
2. Fold up the dust bag (special accessories).
Illustration G
3. Open the dust bag (special accessory) by pulling
back the suction hose port.
4. Close the dust bag (special accessory) tightly with a
cable tie underneath the opening.
5. Take out the dust bag (special accessories).
6. Clean the container inside with a moist cloth.
7. Dispose of the dust bag (special accessory) in ac-
cordance with statutory provisions.
8. Attach new dust bag (special accessories).
9. Pull the dust bag (special accessories) over the con-
tainer.
10. Fit and lock the suction head.
Cleaning the electrodes
1. Unlock and remove the suction head.
2. Clean the electrodes with a brush.
3. Fit and lock the suction head.
Troubleshooting guide
DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
Note
The device must be switched off immediately if a mal-
function occurs (e.g. filter breakage). The malfunction
must be eliminated before switching the device on
again.
Suction turbine does not start up
1. Check the socket and the power supply fuse.
2. Check the mains cable, mains plug, electrodes and
power socket on the device.
3. Switch on the device.
Suction turbine switches off
1. Empty the container.
Suction turbine does not switch on again after emp-
tying the container
1. Switch off the device and wait for 5 seconds. Switch
on the device.
2. Clean the electrodes with a brush.
Suction power decreases
1. Remove any blockages from the suction nozzle,
suction pipe, suction hose or main filter element.
2. Change the filled fleece filter bag.
3. Change the filled dust bag (special accessories).
4. Correctly engage the filter cover.
5. Change the main filter element.
6. VCL 550 PRO only: Check the drain hose for leaks.
Escaping dust when vacuuming
1. Only with flat fold filters: Check that the flat fold filter
is correctly fitted and correct if necessary.
Illustration P
2. Change the main filter element.
The automatic switch-off mechanism (wet vacuum
cleaning) does not trigger
1. Clean the electrodes with a brush.
2. Continuously monitor the filling level when vacuum-
ing non-conductive liquids.
Automatic filter dedusting not working
1. Suction hose not connected.
The automatic filter dedusting function cannot be
switched off
1. Contact Customer Service.
The automatic filter dedusting function cannot be
switched on
1. Contact Customer Service.
Customer Service department
If the malfunction cannot be corrected, the device must
be checked by the Customer Service department.
Содержание VCL 530 PRO
Страница 3: ...1 2 3 Click 2x 4 5 1 2 1 1 B...
Страница 4: ...C D 2 1 3 1 4 5 5 E 1 3 2 F 2 1 G H 2 1 I Click J...
Страница 5: ...K 2 1 L M N O P...
Страница 75: ...75 VCL 550 PRO 1 1 M 2 1 2 DGUV 1 1 2 N 3 4 5 6 7 8 9 1 2 O 3 4 5 6 7 1 2 F 3 4 5 6 1 2 G 3 4 5 6 7 8 9 10...
Страница 86: ...86 2 F 3 4 5 1 2 G 3 4 5 6 7 8 VCL 550 PRO 1 H 35 I 1 2 1 1 2 0 5 15 3 J 4 5 K 15 AUTO MAX 60 AUTO MIN...
Страница 141: ...141 1 2 VCL 550 PRO 1 1 M 2 1 2 1 DGUV 1 2 N 3 4 5 6 7 8 9 1 2 O 3 4 5 6 7 1 2 F 3 4 5 6 1 2 G 3 4 5...
Страница 165: ...165 1 2 VCL 550 PRO 1 1 M 2 1 2 1 DGUV 1 2 N 3 4 5 6 7 8 9 1 2 O 3 4 5 6 7 1 2 F 3 4 5 6 1 2 G 3 4 5 6 7 8 9 10...
Страница 170: ......
Страница 171: ......
Страница 172: ...6 2 NN A5 GS 03323...