TS400 & TS410
Installation & User Guide
Compatible Equipment
TS400 REM - Remote Keypad
9040 - Loudspeaker
SD1+ - Speech Dialler
496522 Issue A
1 of 10
Страница 1: ...TS400 TS410 Installation User Guide Compatible Equipment TS400 REM Remote Keypad 9040 Loudspeaker SD1 Speech Dialler 496522 Issue A 1 of 10 TS400 TS410 ...
Страница 2: ...er l Dedicated Final Exit zone l Blind control panel supplied with 1 remote keypad with the option to support up to 4 l Facilities to connect to an SD1 Speech Dialler l 4 event log l Programmable output for vibration detectors or latching PIRs l Dual user codes l Remote Reset facility l 7 0 Ah battery capacity l All data stored in Non Volatile Memory NVM Specifications TS400 Control Panel Input Vo...
Страница 3: ...icator LED is used to indicate the status of the system set or unset It also flashes when the mains power is removed or when the user selects the user program mode Tamp Indicator LED This red LED is used to indicate a system tamper alarm it also flashes when the engineer program mode is selected Note this is not fitted on the TS410 F E Indicator LED This red LED is used to indicate the status of t...
Страница 4: ... P A ZONE 4 FIRE ZONE 3 K Sw ZONE 2 ACCESS ZONE 1 ACCESS FINAL EXIT TS400 TS410 NOTE Any unused zones must be linked out PIRs and Surface Contacts may be connected to any zone This diagram is only used to represent a typical installation example If a keyswitch is fitted it must be connected to Zone 3 and then programmed as KEYSWITCH If a Smoke Heat Detector is fitted it must be connected to Zone 4...
Страница 5: ...of the tamper switch spring and the cover is securely clipped to the base Extension Loudspeakers A 16 Ohm extension loudspeaker can be connected between the L S and AUX 12V terminals R37 located in the top left hand corner of the PCB can be cut to reduce the volume of the internal sounders alarm is always full volume ALM Terminal This terminal is switched negative 100mA on alarm and is removed whe...
Страница 6: ...ty User Reset Number Of Rearms 3 Operation Of Keyswitch Away Set Full RST Output Detector Reset HOME Set Configuration Zone 1 Omitted Factory Default Settings 2 Switch on the 240V mains supply when the green UNSET LED is lit remove the screwdriver blade The internal alarm will sound and the TAMPER LED will light 3 Enter the engineer s passcode default 1 2 3 4 the alarm will silence Enter the engin...
Страница 7: ...ttery 2 Place a small screwdriver blade between the pins on the control panel PCB marked Factory Restart 3 Power up panel battery and mains 4 Remove screwdriver 5 Enter 1234 to silence alarm 6 The system will have reverted back to Factory Default Programming Bell Test Walk Test Please refer to user s menu numbers 1 and 2 respectively 496522 Issue A 7 of 10 TS400 TS410 TS400 TS410 ...
Страница 8: ...1 to 4 Press 0 to end 1 2 3 4 10 seconds 30 seconds 1 minute 2 minutes 6 Bell Duration Press 1 5 Press 0 to end 1 2 3 4 5 90 seconds 3 minutes 10 minutes 20 minutes Continuous 7 Change Engineer s Passcode Enter new passcode twice Zone LEDs 1 4 will light as code is entered each LED will go out one by one 8 Remote Reset No Enter reset number twice Zone LEDs 1 3 will light as code is entered each LE...
Страница 9: ...ME HOME Bell Test Walk Test Change Passcode 1 Change Passcode 2 Home Set Configuration Return to unset mode Press twice when the system is in the unset mode to select Chime zones 1 2 3 4 5 TAMPER UNSET FINAL EXIT 1 2 3 4 5 TAMPER UNSET FINAL EXIT HOME 5 6 7 Enter first 3 digits of passcode then e g ...
Страница 10: ...TS400 TS410 10 of 10 496522 Issue A TS400 TS410 This page intentionally left blank ...