Mentor MultiConnect Скачать руководство пользователя страница 1

 

Hardware Installation 

Guide 

MultiConnect

Содержание MultiConnect

Страница 1: ...Hardware Installation Guide MultiConnect ...

Страница 2: ......

Страница 3: ... Les Utilisateurs Au Canada 5 1 MultiConnect NMB 003 Classe B 5 Required Items 5 Installation 7 1 General 7 2 MultiConnect Mounting Plate 9 3 MultiConnect Connections 10 4 Cabling 11 5 Communications Device 12 6 Antenna Installation 12 RF Radiation Specs 14 1 FCC Radio Frequency Exposure Rules 14 2 How to Comply with FCC SAR MPE Guidelines 14 3 SAR and MPE Limits 14 4 Labeling 14 Basic Operation 1...

Страница 4: ...MultiConnectHardwareInstallationGuide 1_2 doc April 8 2004 Page 2 of 17 Suite 230 2891 Sunridge Way NE Calgary Alberta T1Y 7K7 Phone 403 777 3760 Fax 403 777 3769 5 Compliance 17 ...

Страница 5: ...warning to FCC statements 1 2 JK 2 General Precautions Before using this product be sure to carefully read all operating instructions Save these instructions for future reference Also be sure to heed all the warnings located throughout this document NOTE Mentor Engineering Inc reserves the right to change specifications without notice Please ensure you have the most recent revision of this Documen...

Страница 6: ... never expose this product to water or operate in a high humidity environment Never use the product around water near a bathtub kitchen sink swimming pool or in the rain WARNING Do not attempt to operate a damaged device If the product has been exposed to water shows evidence of physical damage or is not operating properly unplug it from the power source and refer servicing to qualified service pe...

Страница 7: ...and used in accordance with the instruction manual may cause harmful interference to radio communications in which case the user will be required to correct the interference at their own expense The user of this equipment is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment EMISSIONS COMPL...

Страница 8: ...ConnectHardwareInstallationGuide 1_2 doc April 8 2004 Page 6 of 17 Suite 230 2891 Sunridge Way NE Calgary Alberta T1Y 7K7 Phone 403 777 3760 Fax 403 777 3769 Laptop PC MultiConnect Debugging Cable Multimeter ...

Страница 9: ...7K7 Phone 403 777 3760 Fax 403 777 3769 INSTALLATION 1 General The MulitConnect is an external modem that can interface to any type of host via an RS232 interface It is designed to be installed inside of a vehicle It can be equipped with several different RF Modems An RS232 RJ45 port is also available for operator debugging ...

Страница 10: ...MultiConnectHardwareInstallationGuide 1_2 doc April 8 2004 Page 8 of 17 Suite 230 2891 Sunridge Way NE Calgary Alberta T1Y 7K7 Phone 403 777 3760 Fax 403 777 3769 Figure 1 Typical System Schematic ...

Страница 11: ...ng the MultiConnect out of sight not only increases the aesthetic properties of the installation but also limits the access by drivers and passengers to the cabling The Mounting plate is first fastened to the car interior using bolts or other appropriate means Hardware has not been supplied for this step as it will vary depending on the thickness and type of material the mounting plate is attached...

Страница 12: ...ne 403 777 3760 Fax 403 777 3769 3 MultiConnect Connections The cable cover on the MultiConnect unit can be removed by hand or by using a flathead screwdriver to loosen the two screws Removing the cable cover gives access to the MultiConnect interface points which are detailed below Figure 2 MultiConnect Interface points Rear View ...

Страница 13: ...the environment Mentor Engineering recommends that this practice be followed in all installations If an external host device i e an MDC is being used with the MultiConnect the installer must ensure that there is a common ground between the devices MultiConnect power leads can be crimped onto the power leads at the power input to the host device Installing the power leads in this way will avoid the...

Страница 14: ...ds using a roof top antenna installed in the center of the vehicle roof for best coverage and to meet SAR MPE radiation specifications See Following section RF Radiation Specifications Antenna installation requirements vary between different antennas Contact Mentor for specific Antenna information for your application The following Figure shows the preferred location of a rooftop antenna Figure 4 ...

Страница 15: ... sharp bends and moving objects in the coaxial cable path Position the antenna away from fuel caps Position the antenna such that there is separation from other antennas e g AM FM Radio cellular etc Follow the antenna manufacturer s guidelines exactly when installing antennas WARNING The MultiConnect must be used with a Mentor authorized antenna in order to comply with FCC regulations Improper ant...

Страница 16: ...his and to ensure optimum antenna performance Mentor Engineering recommends that antenna be installed in the center of the vehicle rooftop WARNING The user should be instructed to maintain the minimum distance from the antenna 3 SAR and MPE Limits SAR limits for General Population Uncontrolled exposure is 1 6W kg for partial body exposure averaged over 1 g of tissue and 4 W kg for hands wrists and...

Страница 17: ... Fax 403 777 3769 final device configuration cannot be met due to occasional non essential operating conditions or requirements An example statement is shown below Warning To meet the FCC RF exposure requirement for mobile transmitter end products ensure that the antenna is at least 25 cm 10 away from the user or nearby persons when transmitting ...

Страница 18: ...lly turns on when the vehicle ignition line is active or when the Debug Cable is inserted 2 General Handling and Maintenance Care should be taken in handling the MultiConnect to prolong product life Caution should be used to prevent liquids from entering any openings on the unit Liquid spills could seriously damage the internal contents of the unit 2 1 Cleaning Tips Use a soft lint free cloth mois...

Страница 19: ...Operation at temperatures outside this range in not recommended Some modems are not intended for operation at the extremes Storage 40 to 80 C 40 to 176 F 4 Dimensions and Weight Approximate Size L x W x H 4 75 x 5 0 x 1 0 121 x 127 x 25 mm Weight with typical modem 0 77 lbs 0 35 kg 5 Compliance FCC Class A Part 15 NOTE Mentor Engineering Inc reserves the right to change specifications without noti...

Отзывы: