Instruction Manual For ShellPa Pro (Model type : STMP) 

Page(1/32) 

Lifescience  Dept.  Menicon  Co.,Ltd. 

 
 
 
 
 
 

Instruction Manual 

For ShellPa Pro (Model type : STMP) 

 

 

 

 

Содержание ShellPa Pro

Страница 1: ...SP_Inst02 02_20220208 Instruction Manual For ShellPa Pro Model type STMP Page 1 32 Lifescience Dept Menicon Co Ltd Instruction Manual For ShellPa Pro Model type STMP...

Страница 2: ...stretch and relax parameter P13 Setting Stretch ratio Setting Stretch and relax speed time 3 3 Operating to start and stop P15 Start operation Stop operation Forced Stop 4 Cycle Stop system mode P17 4...

Страница 3: ...Hour Meter P25 7 3 Set Position and Pin Gap Adjust P25 8 Maintenance and Overhaul alarm P27 Maintenance When operating time reaches 2 000 hours Overhaul When operating time reaches 8 000 hours 9 Alarm...

Страница 4: ...ipment 1 1 Checking the supplied items First please check there are below units and parts Operation unit 1unit Control unit 1 unit Stretch chamber holder 1holder Cover plate 5plates Stretch chamber SC...

Страница 5: ...eration unit Control unit Stretch chamber holder Connecting cable Stretch and relax point bar Rigid point bar Access cover Power cable connector Main switch Main display Fuse Connecting cable Vent hol...

Страница 6: ...gure1 Connecting and setting ShellPa Pro Beforehand cleaning up closely inside and outside of operation unit and stretch chamber holder using ethanol After install it into incubator Like figure1 pleas...

Страница 7: ...tacle in chamber holder setting area on Operation unit 1 Please turn on a main switch on Control unit if nothing 2 Initial set up movement on Operation unit start start to move in order to return to o...

Страница 8: ...ain menu H C Stretch Stop system Setting Parameters H C Operating Pattern A Operating Pattern B1 Operating Pattern B2 Operating Pattern C Same layout for PatternB1 Same layout for PatternC Same layout...

Страница 9: ...ng Pattern A Setting Setting parameter of stretch and relax movement in Pattern A Data Output Output data parameter wave record etc of stretch and relax movement in Pattern A Stretch Stop system Monit...

Страница 10: ...chamber Photo Cell seeding on and cell attaching to Stretch chamber in Menicon Co Ltd Cell L929 Chamber SC4Dea Check time 24h after seeding You can use SC4Dea or SC4Ha We recommend quantity of cultur...

Страница 11: ...Please check below explanation of each pattern Pattern A Sq Tri ST Square wave Standstill You can practice stretch and relax cell culture on constant speed And you can set standstill time Please refe...

Страница 12: ...t standstill time in addition to Pattern B1 If retention time set on zero movement will be the same as PattenB1 Please refer to wave on Operating Pattern screen below Pattern C Twice square wave Stand...

Страница 13: ...is 20mm Stretch ratio 1 1 Stretch length is 0 2mm Stretch ratio 20 Stretch length is 4 0mm Setting Stretch and relax speed time Here we explain about Stretch and relax speed time on a case of pattern...

Страница 14: ...ameter on Pattern B2 Parameter sign Contents Input area A One cycle time Cannot input data B Stretch movement time to specified stretch ratio length 0 25 30 00sec C Retention time on stretch 0 0 sec 8...

Страница 15: ...initial position 0 0 sec 86400 0sec 24h 3 3 Operating to start and stop Start operation 1 Chose which pattern of stretch on main menu screen Display will go to Operating Pattern screen you had chosen...

Страница 16: ...tention START button is flashing and STOP button is lighting when machine completely stop And SET Position is displayed and light same its around area SET Position indicates that stretch and relax poi...

Страница 17: ...mode Setting On Main menu screen please set off Stretch Stop system because Cycle Stop system and Stretch stop system cannot be used at the same time Next go to Operating Pattern setting screen on eac...

Страница 18: ...stretch and relax cycle until stop as Remaining Count on Operating Pattern screen is displayed Remaining Count on Operating Pattern setting screen is displayed in Remaining Count on Operating Pattern...

Страница 19: ...retch Stop system mode ON OFF Stretch Stop System ON Stretch Stop System ON sign and button light on Stretch Stop System OFF Stretch Stop System OFF sign and button light off 5 2 Stretch Stop system m...

Страница 20: ...cycle stretch and relax movement Stretch Stop system changes from Stretch Time mode to Stop Time mode Therefore there is possibility to take Stretch Time take time longer than setting time refer to e...

Страница 21: ...ystem Number of sets is full below screen will be displayed on Operating Pattern screen and RESET button on Stretch Stop system Monitoring screen and is flashing And Stretch and relax movement stops A...

Страница 22: ...ard or taking out and in SD card clear reset bar graph because this bar graph directly does not check SD card SD card insert On case of no SD card Memory No Set is displayed on Main menu screen SD car...

Страница 23: ...cond after it change over from SD card to USB First Store Data in SD card Please Check Stretch and relax wave data displayed on Operating Pattern data output screen If O K Please press and hold for 3...

Страница 24: ...he display change from USB memory to SD card USB memory screen Next Select Display data on SD card USB memory screen Started to write data to USB and Not pull out USB is displayed When writing data on...

Страница 25: ...Hour Meter You can check total operation time on this machine But you cannot change this number check only 7 3 Set Position and Pin Gap Adjust These parameters mean Set Position Position to set Chamb...

Страница 26: ...tion Manual For ShellPa Pro Model type STMP Page 26 32 Lifescience Dept Menicon Co Ltd Stretch and relax movement Push Stop Pin Gap Adjust Set Position Stationary Attention Machine is always located o...

Страница 27: ...e just information Therefore on these alarms equipment can operate ordinary Maintenance When operating time reaches 2 000 hours Maintenance alarm flashes on Main menu screen when operating time reache...

Страница 28: ...il Alarm contents Please check below table6 Alarm sign Table6 Alarm sign Alarm sign Contents Memo MC20V Alarm Power Off Internal calculation error Controller equipment system have abnormality Please t...

Страница 29: ...Check machine stops or STOP button lighting off on Operating pattern screen You can change Operating pattern screen to Main menu screen when Stretch and relax movement completely stops It is interlock...

Страница 30: ...m H155 Connecting cable length 2 3m Mass Approx Operation unit 5 8 kg Control unit 3 7kg Power requirement 100 to 240V 47 to 63Hz Output Voltage D C 24V 2 5A 60W Stretch ratio Input ratio range 1 to 2...

Страница 31: ...he dish to completely cover the bottom of the chamber 4 Incubate the dishes for 30 minutes to 4 hours at 37 C If the coating is not sufficient please extent the incubation time 5 Remove the coating so...

Страница 32: ...add 1 to 1 5 mL of the diluted PDL solution 2 to the chamber Gently tap the dish to completely cover the bottom of the chamber 4 Incubate the dishes for 1 to 4 hours at 37 C If the coating is not suff...