85-03-01205
ML-SERIES FIREPLACE
Page
70
4.14
LIGHTING CHECKLIST
Be sure to check these items before final operation of the Fireplace.
☐
All items on "Installation Checklist" must be completed.
☐
Carefully follow all lighting and log installation instructions. Make certain that pilot flame and burner light correctly.
☐
Gas leaks and gas pressures prior to installing facing materials is checked.
☐
Fresh batteries are in remote control. Follow “First
-
Time Lighting Instructions” to synchronize the remote control and the
ignition module.
☐
Air shutter opening 0" to ⅛" natural gas or ¼” to ½” LP gas is
checked.
☐
Flame is "stable" and does not "lift" off burner. If flame lifts off burner, turn unit off and check that all vent pipes are "twist
locked" and leak proof, the vent cap is "right side up”. Do not proceed with operation if flame is
"lifting off" burner.
☐
DO NOT proceed with operation unless burner cycles "on/off" without delays and the flame is "stable" and not "lifting" off
burner after 5 minutes of initial ignition.
Caution: If ignition syste m goe s into loc kout mode , be sur e to wait a minimum of five minute s be for e
r e lighting.
4.15
AIR SHUTTER CONTROL AND FLAME APPEARANCE
During initial installation, the air shutter opening should be checked to be certain that the shutter is set correctly at 1/8 " open
for natural gas and 1/2" minimum open for L.P. gas.
NOTE: For altitudes above 5,000’
, some variations may be required.
Be sure burner and logs are properly installed. After log set has been properly installed, adjustments to the air shutter shall be
made for final flame appearance. These small shutter adjustments can be made by the following procedure:
NO TE: A ll adjustme nts to the air shutte r se tting must be made by a qualifie d installe r , se r vic e age nc y, or the
gas supplie r . Ve r y small c hange s in shutte r se ttings make major c hange s in fl ame appe ar anc e .
The burner air shutter adjustment cable is located on the right side of the fireplace. It is located at the bottom of the right-side
air gap. The shutter cable can be accessed through the air gap and adjusted using the glass latch tool. To open or close the air
shutter insert the glass latch tool tip in the ring terminal’s ring hole.
Push the cable to close the air shutter or pull on the cable
to open the air shutter. The ML72 will have two air shutter adjustment cables, one for the front burner and one for the rear
burner.
1.
If flame is too blue, close air shutter in small 1/8" increments until flame turns desired realistic yellow. Use glass latch
tool to hook end and slide control.
2.
If flame is causing soot on viewing glass, open air shutter fully until sooting stops. Continue burning unit with air
shutter fully open for four to six hours until all internal deposited soot has burned off.
3.
Once deposited soot has disappeared, close air shutter in incre
ments of 1/8”.
L PG A ir shutte r se ttings hint: A pr ope r ly adjuste d air shutte r se tting will yie ld bur ne r flame s that have an
appr ox imate 2 ” high blue c olor base . If ye llow c olor e d flame s ar e star ting at bur ne r le ve l, air shutte r is
c lose d too far and wil l c r e ate soot. If you obse r ve that the flame is ye llow star ting ve r y c lose to or at the
bur ne r sur fac e le ve l, ope n air shutte r . A lso, if a log or par t of a log is suspe nde d and hanging inside a ye llow
por tion of the flame , soot c an for m e asily on the par t of the log that is inside the ye llow flame ar e a.
IMPO RTA NT: Tr y e ac h ne w shutte r se tting appr ox . ½ hr . be for e mak ing additional c hange s.
Содержание ML39- AA-11-04391
Страница 2: ...85 03 01205 ML SERIES FIREPLACE HOMEOWNER NOTES...
Страница 16: ...85 03 01205 ML SERIES FIREPLACE Page 16 Figure 3 10 Figure 3 9...
Страница 87: ...85 03 01205 ML SERIES FIREPLACE Page 87 ML72 Gas Train Assembly Parts...
Страница 94: ......
Страница 95: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...