PF2 Ignition System Diagram
Note: Connect wires in junction box located on the right
side of this appliance to house power using supplied wire
nuts.
Note : O n Dé c or mode ls, the Split Flow c ir c uit is
only use d on the ML 7 2 .
Replacement wires must have the same type and size of
insulation as the original.
This appliance must be electrically connected and grounded
in accordance with local codes or, in the absence of local
codes, with the current NFPA 70- National Electric Code or
CSA C22.1- Canadian Electrical Code.
Label all wires prior to disconnection when servicing control.
Wiring Errors can cause improper and dangerous operation.
Verify proper operation after servicing.
3.3.4
Wi-Fi Dongle and Application
This appliance has the capability to be controlled via an application through Wi-Fi. The Wi-Fi dongle is factory installed and wired
between the dongle and the control module. The Wi-Fi dongle shall be attached to the RH access panel assembly with Velcro. The
Wi-Fi dongle is equipped with a reset button for if there are connectivity issues between the fireplace and phone application. T o
reset the Wi-
Fi connection press and hold the button to reset the connection. The application is called “Proflame Connect”
and is
available in your phone’s app store. Please see the “Proflame WIFI Dongle; Use and Installation Instructions” PDF for install
ation
and use instructions.
ML72 ONLY
Содержание ML39- AA-11-04391
Страница 2: ...85 03 01205 ML SERIES FIREPLACE HOMEOWNER NOTES...
Страница 16: ...85 03 01205 ML SERIES FIREPLACE Page 16 Figure 3 10 Figure 3 9...
Страница 87: ...85 03 01205 ML SERIES FIREPLACE Page 87 ML72 Gas Train Assembly Parts...
Страница 94: ......
Страница 95: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...