background image

 

 

MENDOTA GAS DIRECT VENT FIREPLACE  

with 

Premium Texture Fiber Logs Combustion System 

Model DXV-35 DT3 - LX 

INSTALLATION & OPERATING INSTRUCTIONS 

 

NO. LX-

11

11 

 

WARNING 

If you do not follow these instructions exactly, a fire or 

explosion may result causing property damage, personal 

injury or loss of life. 

 

CAUTION: Keep gasoline and other liquids having flam-

mable vapors away. 

 

WHAT TO DO IF YOU SMELL GAS 

 

Do not try to light any appliance. 

 

Do not touch any electrical switch; do not use any 

phone in your building. 

 

Immediately call your gas supplier from a neighbor's 

phone.  Follow the gas supplier’s instructions. 

 

If you cannot reach your gas supplier, call the fire 

department. 

WARNING 

Do NOT use this appliance if any part has been under water.  

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control system and 

any gas control, which has been under water.

 

AVERTISSEMENT. Quiconque ne respecte pas à la lettre 

les instructions dans la présente notice risque de dé-

clencher un incendie ou une explosion entraînant des 

dommages, des blessures ou la mort.

 

ATTENTION. Garder l’essence ou autres liquides produi-

sant des vapeurs inflammables loin del’appareil.  
 
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ : 

 

Ne pas tenter d’allumer d’appareil.  

 

Ne touchez à aucun interrupteur; ne pas vous servir 

des téléphones se trouvant dans le bâtiment. 

 

Appelez immédiatement votre fournisseur de gaz 

depuis un voisin. Suivez les instructions du fournis-

seur. 

 

Si vous ne pouvez rejoindre le fournisseur, appelez 

le service des incendies. 

N’utilisez pas cet appareil s’il a été plongé dans l’eau, 

même partiellement. Faites inspecter l’appareil par un 

technicien qualifiéet remplacez toute partie du système 

de contrôle et toute commande qui ont été plongés dans 

l’eau.

 

AVERTISSEMENT : 

Une installation, un réglage, une modifi-

cation, une réparation ou un entretien mal effectué peut cau-

ser des dommages matériels ou des blessures. Voir la notice 

de l'utilisateur quiaccompgne l’appareil. Pour de l’aide oueds 

renseignements supplémentaires, consultez un installateur, 

un technicien agréé ou le fournisseur de gaz.

 

WARNING

:    Improper  installation,  adjustment,  alteration, 

service or maintenance can cause injury or property damage.  

Refer  to  this  manual.    For  assistance or additional informa-

tion  consult  a  qualified  installer,  service  agency  or  the  gas 

supplier. 

Содержание DXV-35 DT3 - LX

Страница 1: ...essures ou la mort ATTENTION Garder l essence ou autres liquides produi sant des vapeurs inflammables loin del appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne...

Страница 2: ...est fournie WARNING Do not operate this appliance with the glass removed cracked or broken A licensed or qualified person should do replacement of glass This appliance must be installed in accordance...

Страница 3: ...IR SHUTTER SYSTEMS Externally controllable Rear Burner air shutter and Internal rotary Front Burner air shutter LOG SET 9 piece Premium Definition Log Set with Extreme glow and realism ember bed REFRA...

Страница 4: ...OMPONENTS TWIST LOCK CONNECTION PROCEDURE 14 GENERAL INSTALLATION INSTRUCTIONS 15 SPECIFICATIONS CLEARANCES 16 TOP FLUE VENTING COMPONENTS 17 FLUE VENTING ALLOWANCE CHART 18 L P GAS MINIMUM HEIGHT HOR...

Страница 5: ...OCEDURE TO CONVERT THIS FIREPLACE TO BURN LPG 49 INSTALLING THE LP PRESSURE REGULATOR 52 LP GAS PRESSURE REQUIREMENTS 53 LPG PROPER INPUT RATES 53 LEAK TESTING REQUIREMENTS 53 PILOT FLAME AND MAIN BUR...

Страница 6: ...tified by a nationally recognized testing and certification agency to American National Standards Institute ANSI Gas Appliance Safety Standards The Mendota Gas DXV Fireplace has been tested and certif...

Страница 7: ...ilding Code 3 A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a min imum height of eight 8 feet above grade directly in line with the exhaust ve...

Страница 8: ...ds of high surface temperature and should STAY AWAY to avoid burns or clothing ignition Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance These units MUST u...

Страница 9: ...y by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material carbon build up etc It is imperative that control compart ments burners...

Страница 10: ...ower grills Always use Mendota grills and Mendota approved vent systems and vent caps A non combustible hearth protector is required and must extend a minimum of 12 in front of the fireplace If fire p...

Страница 11: ...oaxial Vent Pipes AMERIVENT DURAVENT SELKIRK METALBESTOS SECURITY CHIMNEY and ICC brand pipes and venting compo nents may be used when venting off the top TOP VENTING Venting off the top on the DXV 35...

Страница 12: ...ring any pressure testing of the gas supply piping system at test pressures of PSIG 3 5 kPa equal to or less than A proper gas line diameter must be selected to run from the supply regulator to the Fi...

Страница 13: ...enter the residence in which case pounds to inches regulators are used The most important item to check during the installa tion and the first thing to check when problems occur is gas pressure The f...

Страница 14: ...ve the terminal from the center line of the ter minal 12 inches 30 cm minimum Vinyl surfaces require 24 min K Clearance to a mechanical air supply inlet 6 feet 1 8 m minimum E Clearance to unventilate...

Страница 15: ...nother solid fuel or gas burning appliance Each direct vent gas appliance must have its own separate vent sys tem Common vent systems are prohibited To assure proper venting performance of the high pe...

Страница 16: ...WELLINGTON TRIMS may not 5 Level the Fireplace and secure into opening by nailing through the nailing flanges on cabinet side panels Holes are provided in fireplace floor behind grill to secure firepl...

Страница 17: ...NTEL DEPTH INCREASE TRIANGULAR AREA FOR COMBUSTIBLE MANTEL 12 FOR EVERY 1 THE FIREPLACE IS RAISED OFF THE FLOOR HEARTH PROTECTOR MAY BE REDUCED BY 2 IF FIREPLACE IS RAISED 6 OR MORE NO HEARTH PROTECTI...

Страница 18: ...7 PIPE 9 ATTIC INSULATION SHIELD 12 10 ROOF FLASHING 0 12 TO 6 12 10 ROOF FLASHING 7 12 TO 12 12 11 STORM COLLAR 12 VERTICAL VENT CAP 13 SUPPORT BAND 14 HORIZONTAL VENT CAP 15 FIRESTOP SPACER Figure 5...

Страница 19: ...NOTE FOR LPG AND HIGH ALTITUDE APPLICATIONS SEE PAGE 19 NOTE Figure 6 DXV35 Vertical Horizontal Vent Requirements 12 MINIMUM VERTICAL PIPE CAN BE USED IF NO HORIZONTAL VENT SECTIONS GREATER THAN 6 or...

Страница 20: ...equires 22 minimum height to center of vent cap CAUTION If 90 elbows must be used a 24 inch vertical starter section must be used off the top of the fireplace L P GAS OR HIGH ALTITUDE ABOVE 4 000 FT B...

Страница 21: ...ngle opening in the wall The hole must be positioned so the vent system will run level or have a rise AND be perpendicular to the wall The height of the opening must be located to meet all lo cal and...

Страница 22: ...RT PLATE 45 01 00201 FLASHING 0 12 6 12 PITCH 45 01 00202 FLASHING 6 12 12 12 PITCH 45 01 00203 STORM COLLAR 45 01 00204 ATTIC INSULATION SHIELD 45 01 00206 CO LINEAR APPLIANCE ADAPTOR 45 01 00207 CO...

Страница 23: ...suring the total vent pipe run so you can more accu rately locate the point where the vent pipe will penetrate the outside wall See Figure 2 Exterior Vent Locations PG 13 Be sure all vent components a...

Страница 24: ...pening should be a sufficient size to meet all clearance requirements Continue to assemble lengths of pipe and elbows necessary to reach up through the roofline Galvanized pipe and elbows may be utili...

Страница 25: ...frame 2 Pull Glass Latch Tool outward about 3 8 3 Rotate Glass Latch Tool 90 degrees 4 Slowly Release Glass Latch Tool 5 Remove Glass Latch Tool To Latch Glass Frame Latches reverse steps 5 to 1 abov...

Страница 26: ...s Appliance Company Contact your dealer for more detailed ordering information GLASS FRAME ASSEMBLY REPLACEMENT PARTS LIST ITEM PART NUMBER DESCRIPTION 1 HA 30 00411 FRAME WELDMENT GLASS DXV35 DT 3 2...

Страница 27: ...logs Coals must not block pilot or burner flames Heat can be reduced by lowering flame height by turning the HI LO knob Blowers can also be turned down to reduce heat output Placement of coals has a b...

Страница 28: ...PLACE LOG 1 REAR LOG ON REAR SHELF BEHIND REAR BURNER PUSH LOG INTO RECESS IN BACK BRICK PANEL LOG 1 RECESS IN BACK BRICK PANEL THE RECESS SHAPE MATCHES THE LOG SHAPE LOG 1 27...

Страница 29: ...N REAR AND FRONT BURNER PLACE LOG 2 BETWEEN THE TWO BURNERS AND SLIDE TO THE RIGHT UNTIL THE CURVATURE IN LOG 2 THE FRONT BURNER CONTACTS THE CURVATURE ON THE RIGHT FRONT TIP OF LOG 2 PUSH LOG 2 DOWN...

Страница 30: ...E BOX ALSO THERE IS A NOTCH THAT MATES WITH THE LEFT MOST GRATE BAR SET LOG 3 ON THE GRATE BAR AND THE RECTANGLE SHAPED AIR SHUTTER BOX TOP SURFACE LOG 3 MUST LEAVE CLEARANCE FOR THE REAR BURNER PORTS...

Страница 31: ...Y IS ALLOWED TO LOG 4 AROUND THE PIN AND HOLE HOWEVER DO NOT ROTATE REAR END OF LOG OUTWARD ROTATE INWARD ONLY IF DESIRED ROTATING OUTWARD MAY PLACE LOG 4 ON TOP OF ROTATING OUTWARD MAY PLACE LOG 4 ON...

Страница 32: ...WITH THE LEFT SIDE PIN ON LOG 1 THE V NOTCH BETWEEN THE TWO BRANCHES MUST SIT DIRECTLY ON TOP OF PIN FOR LOG 5 THE REAR BURNER S LEFT SIDE PORTS AND MUST ALLOW THE FLAMES TO RISE INTO THE V NOTCH IN T...

Страница 33: ...TO MATE WITH THIS PIN LOG 1 PLACE LOG 6 ON TOP OF LOG 1 S PIN THE OTHER END OF LOG 6 SITS ON TOP OF LOG 2 AS SHOWN BELOW SOME ROTATIONAL FLEXIBILITY IS ALLOWED FOR LOG 6 THE POSITION OF LOG 4 WILL LIM...

Страница 34: ...BURNER S REAR VISIBLE EDGE AND ON TOP OF LOG 4 THIS LOG IS DESIGNED TO HIDE THE PILOT LIGHT PLACE THIS LOG SO IT PROVIDES CLEARANCE TO ALL BURNER FLAMES AND PILOT FLAMES YET POSITIONED TO HIDE THE PIL...

Страница 35: ...HERE LOG 8 SITS ON TOP OF LOG 2 AND RESTS AGAINST THE GRATE BAR 2 ND FROM LEFT LOG 8 ATTEMPT TO POSITION LOG 8 AS SHOWN HERE FOR THE BEST GLOW EFFECT AND REALISTIC LOOK DO NOT PINCH FRONT BURNER PORT...

Страница 36: ...TS AND NOT PLACE THIS LOG DIRECTLY ON TOP OF THE FRONT BURNER PORTS AND DO NOT PLACE THIS LOG ON TOP OF LOG 2 SCATTER SMALL COALS ON THE FLOOR AND BETWEEN THE LOG GRATE S HORIZONTAL BAR AND THE FRONT...

Страница 37: ...COMPLETED LOG SET ASSEMBLY 36...

Страница 38: ...vice and gas supply must be installed in accordance with instructions and local and national codes LIGHTING CHECK OFF LIST All items on Installation Check Off List see above must be completed Connect...

Страница 39: ...ition NOTE Mendota Fireplaces recommends that the Standing Pilot Mode be used during the winter months when external temperatures fall below 50 o F This will keep the fireplace chimney heated for prop...

Страница 40: ...P button until the desired temperature is displayed in the SET POINT TEMPERATURE window The fan will turn on 5 minutes after fireplace startup and will turn off 12 1 2 minutes after the flames turn of...

Страница 41: ...f in Standing Pilot Mode the pilot light will remain ON Note If in SMART model the flame height function is not available for manual adjustment In SMART mode the flame height regulates automatically F...

Страница 42: ...eries depends on various factors quality of the batteries used the number of ignitions of the appliance the number of changes to the room thermostat set point etc When the Transmitter bat teries are l...

Страница 43: ...Lock out mode slide Receiver Switch to OFF and toggle Standing Pilot ON OFF Switch to OFF wait 30 seconds and slide back to Remote Repeat this sequence until the pilot flame lights and the pilot is b...

Страница 44: ...eeded OPERATING DURING POWER OUTAGES This electronic ignition system utilizes the supplied 110VAC power when it is available for all functions of this system If the AC power is interrupted during a po...

Страница 45: ...inated Please allow adequate operational time a minimum of 2 weeks for the blowers to break in before you contact your dealer for service WARNING Label all wires prior to disconnection when servicing...

Страница 46: ...ner and logs are properly installed After logs have been properly installed and operated for one to one and a half hours small additional adjustments to the air shutter may be necessary for final flam...

Страница 47: ...Interior glass surface should be cleaned using only soap and water or KEL KEM Polish Plus or comparable product CAUTION Do not use oven cleaner to clean glass Never touch glass or attempt to clean wh...

Страница 48: ...ota service person contacted Be sure logs are re installed per instructions D Check condition of glass door gasket gasket must seal tightly over firebox replace if necessary E Periodically check to ve...

Страница 49: ...SCHEMATICS Note The DXV35 DT3 LX ignition system utilizes Transformed DC power for normal ignition functions In the event of a power outage the Battery Pack power is utilized IGNITION SYSTEM WIRING S...

Страница 50: ...onal and must be purchased separately LP Conversion Kit HA 30 00507 contains the fol lowing parts One Motorized LP Pressure Regulator 907 012 One LP Pilot Orifice Thimble 977 168 and two Cap Ori fices...

Страница 51: ...ifice thimble 977 168 see Figure below for location To remove Pilot Hood use a screw driver to pry open the Wire Clip that is located at the base of the Pilot Hood Pull Upward and remove pilot hood Us...

Страница 52: ...burner is run ning parallel to front face of unit positioned properly so that the pilot light hood pointing to the left is pointed properly towards the burner s flame propagation ports 13 Make certain...

Страница 53: ...TRUCTIONS WILL RESULT IN A LEAK OR OVERFIRING OF THE APPLIANCE AND CAN LEAD TO AN EXPLOSION OR A FIRE HAZARD 1 Remove the Courtesy Access Panel mounted behind the lower grill and lay down gently witho...

Страница 54: ...olution at all plumbing joints prior to placing this appliance into operation It is recommended that all gas plumbing joints factory installed and field installed are checked for leaks PILOT FLAME AND...

Страница 55: ...it to adjust for varying altitudes the information sticker must be filled out by the installer and adhered to the appliance at the time of conversion Cet appareil est equip pour des altitudes compries...

Страница 56: ...NT BURNER TUBE WELDMENT 15 02 00065 L H BLOWER WITH MOTOR HA 30 00510 VALVE ASEMBLY DXV35 DT3 05 01 00157 SNAP DISC FAN TEMP SENSOR 10 03 00068 REAR FLAME WIRING W SWITCH 10 01 00003 RHEOSTAT BLOWER S...

Страница 57: ...in the diagram below Any material that protrudes into this area on the sides top or bottom edges can only be flush with the front surface of the fireplace faceplate If planning to install either the...

Страница 58: ...The top and sides of these trim kits fit within the inner perimeter of the Fireplace s Facep late The bottom member of this trim however over laps the bottom 2 black boarder of the fireplace front fac...

Страница 59: ...58 RATING LABEL REPRESENTATION DXV35 DT3...

Страница 60: ...59 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 61: ...aximum vertical horizontal and vent runs CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES VENT LOCATIONS Per Manual INSTALL PROPER SIZE GAS LINES CHECK FOR GAS LEAKS Per Manual CHECK FOR CORRECT GAS PRESSU...

Страница 62: ...61 TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...

Страница 63: ...formance of any part of this limited warranty Mendota has the right to investigate and inspect the exact original Fireplace and entire installation without any alterations or tampering in the event a...

Страница 64: ...Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division WEBPAGE www johnsongas com or www mendotahearth com Document 85 03 00844...

Отзывы: