85-03-01071
D30 DEEP TIMBER
Page
20
Hearth Pad Requirement
A non-combustible hearth protector with a thermal insulation rating of R-1 is required when installing this fireplace insert
directly on the floor and must extend a minimum of 16" in front of the fireplace insert.
For every 1” the
fireplace insert is raised off the floor, the depth of the required hearth protector may be
reduced by 2”.
If fireplace insert is raised off the floor 6" or more, no hearth protector is required for fire
protection.
Pre-existing non-combustible hearth pads are approved. New hearth pads installed are required to have a thermal insulation
value of R-1.
Caution: The fireplace insert creates localized heat and causes thermal expansion of adjacently installed
flooring and wall materials . Vinyl floors and floating Engineered wood floors may warp if installed in front
of this unit even when this fireplace insert is
raised 6” or more due to local heating up of the floor
materials. Never use vinyl or Engineered wood flooring in the hearth pad area in front of this fireplace
insert
unless you plan to raise this unit 12” or more above the f
loor level.
Caution: Modern carpets use polypropylene, nylon or polyester fibers in the upper visible layer. These fibers
when exposed to radiant heat can curl and stiffen. It is not possible to prevent radiation effects to the
carpet fibers even when this unit is raised high. Avoid installing carpets in the hearth pad area in front of
this Fireplace insert unless this fireplace insert is raised at least 12 inches above the carpet level .
Figure 3-14 HEARTH PROTECTON PAD
Содержание D40 DEEP TIMBER
Страница 2: ...85 03 01071 D30 DEEP TIMBER Page I...
Страница 15: ...85 03 01071 D30 DEEP TIMBER Page 15 Figure 3 10 Figure 3 9...
Страница 36: ...85 03 01071 D30 DEEP TIMBER Page 36 Blower System Wiring Diagram Figure 3 38 BLOWER SYSTEM WIRING DIAGRAM...
Страница 81: ......
Страница 82: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...