85-03-01154
FV36 DÉCOR
Page
85
5.7
REPLACEMENT PARTS INFORMATION
How to Access Components
The descriptions below show where the main fireplaces components are located and how to access them for service. The
descriptions show how to access the components after the fireplace has been installed. All components are also accessible from
the outside of the unit before the fireplace is installed.
Pilot
: The pilot is in the center of the firebox in the middle of the burner.
Gas Valve
: The main gas valve is located on the left side of the firebox. An inspection panel is provided on the left firebox wall
that allows inspection of the gas valve, wiring, and gas inlet connections.
Complete Valve Assembly
:
To make working on components easier, this fireplace has been designed with the valve, pilot, and
gas lines as part of one assemble that can be removed from the fireplace. To remove the assembly first remove the inspection
panel. This will allow the main gas inlet and wires to the valve and pilot to be disconnected. After disconnecting the gas line and
wires remove the screws from the valve mounting plate (13 on the left side and two on the floor of the firebox). Then remove
the entire assembly from the firebox.
Ignition Control Module
: The ignition control module is mounted on the left on the floor under a heat shield. Access to the
ignition control module is available through the inspection panel. First remove the inspection panel. Then locate the two screws
holding the heat shield in place above the ignition control module. The ignition control module is affixed with Velcro to the floor.
Convection Blowers
: The convection blower
s are mounted on the firebox’s rear
wall. To access the convection blowers, remove
the burner and airbox from the fireplace.
Accent Light
: The accent light is mounted in the firebox top center area. The accent light wire harness is run from the light
housing to the left side and then down to the ignition control module.
Содержание AA-11-04109
Страница 2: ...85 03 01154 FV36 D COR...
Страница 16: ...85 03 01154 FV36 D COR Page 16 Figure 3 11 Figure 3 10...
Страница 24: ...85 03 01154 FV36 D COR Page 24 Clearance from Appliance Side Walls Figure 3 17 CLEARANCE TO BODY...
Страница 87: ...85 03 01154 FV36 D COR Page 87 Gas Train Assembly Parts Figure 5 5 Gas Train Assembly Parts...
Страница 88: ...85 03 01154 FV36 D COR Page 88 Burner Figure 5 6 Burner...
Страница 95: ......
Страница 96: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...