85-03-01154
FV36 DÉCOR
Page
57
3.14
NATURAL GAS TO LPG CONVERSION
WARNING
This conversion kit shall be
installed by a qualified service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly, a fire, explosion o r production of carbon monoxide
may result causing property damage, personal injury or loss of life. The qualified service agency is
responsible for the proper installation of this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specified in the owner instructions supplied with the kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in prop erty damage or personal injury.
A natural gas to LP gas conversion kit #HA-110-00102 must be ordered and installed in this fireplace to burn LP gas.
LP conversion kit #HA-110-00102 contains the following parts: one motorized LP pressure regulator #907.012, one cap orifice
#65-14-00050 (
drill #50),
an L-shaped Torx wrench and an LP conversion label.
Figure 3-41 LP Kit Contents
Procedure to Convert Fireplace for LP Gas
This fireplace arrives from the factory ready to burn natural gas. If you intend to burn LP gas, it is highly recommended that you
convert this fireplace and its pressure regulator, pilot natural gas/LP clip position and burner orifices prior to placing this
fireplace in its fireplace cavity.
Follow the step below to prepare this fireplace for conversion to LP gas:
1.
Using a ¼” hex driver, remove the two screws that secure the airbox to the fireplace
back wall.
2.
Lift up and remove the airbox.
3.
You will now be able to access the burner orifice,
which is located inside the air shutter box. Using a
½” deep well socket wrench, remove
the orifice.
When removing and installing the orifice be sure
to use a wrench to keep the fitting the orifice
screws onto from rotating.
4.
Thread a new #50 orifice on the orifice mounting
brass fitting. Tighten down the orifice.
Figure 3-42 PREPARATION FOR CONVERSION
Содержание AA-11-04109
Страница 2: ...85 03 01154 FV36 D COR...
Страница 16: ...85 03 01154 FV36 D COR Page 16 Figure 3 11 Figure 3 10...
Страница 24: ...85 03 01154 FV36 D COR Page 24 Clearance from Appliance Side Walls Figure 3 17 CLEARANCE TO BODY...
Страница 87: ...85 03 01154 FV36 D COR Page 87 Gas Train Assembly Parts Figure 5 5 Gas Train Assembly Parts...
Страница 88: ...85 03 01154 FV36 D COR Page 88 Burner Figure 5 6 Burner...
Страница 95: ......
Страница 96: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...