background image

10 of 28

Note: If the chimney is externally fi�ed or the stove has been installed
on a larger diameter clay chimney liner then on cold days it maybe
necessary to warm the flue using firelighters prior to ligh�ng with wood.

1. Place two small dry split logs (¼ split) on the fire bed. Kindling stacked as
in the picture which allows combus�on air to flow freely and will aid igni�on.
On top of the kindling two or more non toxic firelighters.

2. Fully slide open (pull out ) the Universal air control (UAC) air slider below

the stove door. Slide out fully to the le� posi�on. The stove now has
a mix of primary air secondary air for start up.

3. Light the firelighters and push door to closed posi�on, latch in 1st
posi�on so the door is open 2 mm. (see picture) This provides addi�onal
combus�on air for start up and reduces condensa�on on the door glass.

HOW TO LIGHT YOUR WOOD BURNING STOVE

The stove will get very hot during use and due care must therefore be exercised.

Please use the glove when opera�ng air controls, door and ashpan.

WOOD FUEL

Good quality wood is the most important factor in your stove working efficiently and cleanly. Always use dry split hardwood
firewood (moisture content of 20% or less). The dryness of the firewood plays an important role since the use of wet wood
results in poor fuel economy and may cause a tarry sooty film on the internals of the stove.

Newly cut wood contains 60–70% water, making it totally unsuitable for use as firewood.

Newly cut wood should be stacked and air dried under cover for two years before being used as firewood.

Do not burn liquid fuels, dri� wood, finished, sawn wood, pallet wood, chipboard/plywood, varnished wood or

plas�c coated wood, wood treated with preserva�ves, or house hold waste.

5. Once the fire bed is established slide UAC control to
the secondary posi�on (right side) and push in slider as
desired, for the stove to burn cleanly plenty of secondary air
is needed, do not be tempted to shut the fire down too early
as this may cause smoke. At nominal heat output, expect to
refuel your stove approximately once an hour. Check load
weights for your model on the table on page 5. And use the
glove when reloading, as well as when opera�ng air controls
and door.

4. Once the flames from the logs are fully established , this can take up to 10 min's . The door can now be closed. Leave the
UACcontrolin thele�posi�on (ifthesliderisinthele�posi�on theaircontrollerisproviding a mix of primary and secondary air).If
the stove flames begin to falter and generate smoke in chamber unlatch the door again un�l the fire is established.

Maximum Primary Air Mix

1.

Arrange your Kindling & Logs as shown

Содержание Christon 550

Страница 1: ...1 of 28 OPERATION AND INSTALLATION MANUAL Woodburning SE models Christon 550 Christon 750 ENG December 2019...

Страница 2: ...y to the country in which your stove is installed and tested These instruc ons cover the basic principals to ensure the sa sfactory installa on of your stove although detail may need slight modifica o...

Страница 3: ...m manufacturer s instruc ons Provision of an alarm must not be considered a subs tute for either installing the appliance correctly or ensuring regular servicing and maintenance of the appliance and c...

Страница 4: ...a on procedure given in BS5854 1980 may be used as the basis for deciding whether a par cular chimney design will provide sufficient draught If it is found that there is excessive draught in the chimn...

Страница 5: ...n 550 750 have been recommended as suitable for use in smoke control areas when burning wood logs and when fi ed with a mechanical stop to prevent closure of the secondary ter ary air control Christon...

Страница 6: ...MENSIONS AND CONNECTION MEASUREMENTS 745 550 10 20 154 355 80 372 5 1 2 5 1 2 5 112 5 105 10 550 550 E E 550 75 75 105 105 275 105 105 136 26 22 5 198 256 11 5 550 10 80 52 1 6 7 Christon 750 Christon...

Страница 7: ...mm thick in accordance with Building Regula ons Approved Document J to a distance of 30 cm in front of the stove and 15 cm to each side measuring from the door of the combus on chamber HEARTH COMBUST...

Страница 8: ...c on to either a masonry chimney or a prefabricated factory made insulated metal chimney COMBUSTION CHAMBERS INSTALLING A CHRISTON INSET N B Inset models are supplied with a stainless steel adapter wh...

Страница 9: ...ernal air is directed into the combus on chamber By moving the control lever to the le increases the primary air mix moving the UAC to the right increases the secondary air Whatever posi on the contro...

Страница 10: ...wood plays an important role since the use of wet wood results in poor fuel economy and may cause a tarry sooty film on the internals of the stove Newly cut wood contains 60 70 water making it totally...

Страница 11: ...ponsible for implemen ng the Clean Air Act 1993 including designa on and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements The Christon 550 750 SE s...

Страница 12: ...bed If thereis insufficientburning materialin the firebed tolight anew fuelcharge excessivesmoke emissioncan occur Refuelling must be carried out onto a sufficient quan ty of glowing embers and ash th...

Страница 13: ...Mendip stoves do not recommend that their stoves are burnt overnight for this reason As a night me regime we recommend that the fireis loadedwhen hotand burntfor fiveminutes withthe secondaryair cont...

Страница 14: ...lit stove The use of any aerosol is dangerous and care must be taken handling aerosols 1 Fire Will Not Burn check a the air inlet is not obstructed in any way b that chimney and flue ways are clear c...

Страница 15: ...tove linings To remove ash pan use a ash shovel always wear a heat resistant glove Make sure the stove is completely cold before cleaning out ash embers can remain hot for over 24 hours Ash must be st...

Страница 16: ...visit www eurostove co uk for latest spare part informa on Always use the opera ng tools provided when handling parts likely to be hot when the stove is in use Your stove has the following parts in t...

Страница 17: ...17 of 28 1 1 7 8 4R 5 3 3 6 2L 1 1 2R 4L 5L 5R CHRISTON 550 750 COMBUSTION CHAMBER SPARE PART CODES...

Страница 18: ...rip on Christon 550 Part Code Christon 750 Part Code 1 Base Brick Pair M10550 02 22 99 00 M10750 02 22 99 00 2 Rear Brick Pair M10550 02 23 99 00 M10750 02 23 99 00 3 Side Brick Pair M10550 02 24 99 0...

Страница 19: ...et Tilt an upper baffle brick forward and to the centre in order to remove Your flue system can now be accessed through the stove but for added protec on when sweeping it is advised that all the brick...

Страница 20: ...20 of 28 Christon 550 Freestanding Inset Christon 750 Freestanding Inset CHRISTON 550 750 COMBUSTION CHAMBER CAN BE REMOVED FROM OUTER FRAME...

Страница 21: ...Christon 550 Inset Christon 750 Inset Christon 750 Freestanding To purchase or get more informa on on spare parts for the Christon Models please visit www mendipstoves co uk mp spares christon catego...

Страница 22: ...0 00 M10750 06 00 00 00 1 Door Handle M10750 06 05 99 00 M10750 06 05 99 00 2 Glass M10550 01 27 99 00 M10750 01 27 99 00 3 Door Rope Seal M10550 06 02 00 00 M10750 06 02 00 00 4 Glass Rope Seal M1055...

Страница 23: ...feet have been removed roughly posi on the stove inline with the base Then carefully li one side of the stove and remove the wooden batons allowing the stove to come to rest upon the logstore 4 It is...

Страница 24: ...ethe topplate protrusionbetween the stove body and the log base If this has been posi oned correctly the threaded holes of the top plate will be accessible through the logstore base of the Christon Th...

Страница 25: ...25 of 28 EN TEST RESULTS CHRISTON 550 Essen al Characteris c Descrip on...

Страница 26: ...26 of 28 EN TEST RESULTS CHRISTON 750 Essen al Characteris c Descrip on...

Страница 27: ...27 of 28 39 of 40...

Страница 28: ...0 750 Manual Version Mendip Stoves Ltd Unit H1 Mendip Industrial Estate Mendip Road Rooksbridge Somerset BS26 2UG Website www mendipstoves co uk Email info eurostove co uk Telephone 01934 750 500 Part...

Отзывы: