4 OF 32
Chimney Connec�on
In order for the stove to perform sa�sfactorily the chimney height must be sufficient to ensure an
adequate draught to clear the products of combus�on and prevent smoke problems into the room.
Tested Gas flow rates flue
gas temperatures
Flue gas flow rate
Wood
Test flue gas temperature
Wood
@ Pascals of pressure
ASHCOTT
4.6/sec
232deg C
12 pa
A chimney height of not less than 4.5 metres measured ver�cally from the outlet of the stove to the top of the chimney should
be sa�sfactory. Alterna�vely the calcula�on procedure given in BS5854:1980 may be used as the basis for deciding whether a
par�cular chimney design will provide sufficient draught.
If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternately a draught
stabiliser should be fi�ed. The adjustable flue damper should not close off the flue en�rely but should in its closed posi�on leave
a minimum con�nuous opening free area of at least 20 % of the total cross sec�onal area of the flue or flue pipe. Adequate
provision e.g. easily accessible soot door or doors must be provided for sweeping the chimney and connec�ng flue pipe.
Your appliance needs to be maintained rou�nely, the throat plate/baffle should be cleaned regularly (monthly). The flue pipe
can be cleaned using a flexible brush. Only Use a dry cloth on external surfaces. Over �me the glass may become dirty, clean
with a damp cloth and polish off with damp cloth. If the stove has not been used for some �me the flue should be checked for
blockages before use. Do not modify the appliance; only use spares authorised by the manufacturer.
STOVE PERFORMANCE & TESTING
Output wood fuel
Efficiency
@ CO@13% O
2
Recommended for smoke
control Oct 2017
ASHCOTT
4.6/sec
80.3%
0.09
Yes / SE model
Mendip Stoves, ASHCOTT model is tested in accordance with EN 13240.
Energy Rating Class
SIA ECO Design 2022
Certified
Index
Seasonal efficiency
ASHCOTT
A+
YES
107
70.3%
Stove model Weight & Nominal heat output for wood and smokeless fuels
Log length
Wood reload
Weight wood load
Wood dimensions
H x W x L cm
ASHCOTT
30cm
~45min
1.0kg
10 x 10 x 30
Distance to Combus�ble materials
Combus�ble materials should not be located where the heat dissipa�ng through the walls of fireplaces or flues could ignite it.
Therefore when installing the stove in the presence of combus�ble materials due account must be taken of the guidance on the
separa�on of combus�ble material given in Building Regula�ons Approved Document J and also in these stove instruc�ons. The
minimum distances to flammable materials are specified on the EN 13240 plate on the back of the stove.
Distance to
combustibles rear
Distance to
combustibles sides
Distance to
combus�bles sides
Convec�on models
Suitable for 12mm non-
combustible floor plate
ASHCOTT
150mm
400mm
n/a
YES