INFORMATION FOR THE USER, INSTALLER AND SERVICE ENGINEER

----------------------------------------------------------------------------------------------------------------------------------------------------------------

Special care must be taken when installing a stove such that the requirements of the Health & Safety at Work Act are met.

Handling

Adequate facili�es must be available for loading, unloading and site handling.

Fire Cement

Some types of fire cement are caus�c and should not be allowed to come into contact with the skin. In case of contact
wash immediately with plenty of water.

PREPARATORY WORK AND SAFETY CHECKS

IMPORTANT WARNING

This stove must not be installed into a chimney that serves any other hea�ng appliance. There must not be an extractor

fan fi�ed in the same room as the stove because this can cause the stove to emit fumes into the room.

Asbestos

This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the coarse of installa�on then please

seek specialist guidance and use appropriate protec�ve equipment.

Metal Parts

When installing or servicing this stove care should be taken to avoid the possibility of personal injury.

CO Alarms:-

Building regula�ons require that whenever a new or replacement fixed solid fuel or wood/biomass appliance is installed in
a dwelling a carbon monoxide alarm must be fi�ed in the same room as the appliance. Further guidance on the
installa�on of the carbon monoxide alarm is available in BS EN 50292:2002 and from the alarm manufacturer’s
instruc�ons.

Provision of an alarm must not be considered a subs�tute for either installing the appliance correctly or ensuring
regular servicing and maintenance of the appliance and chimney system.

Stove paint Aerosols
Paint aerosols are flammable and therefore dangerous to use around a lit stove. Be sure to allow aerosols spray paints
to dry and ven�late the room well before ligh�ng the stove. The use of any aerosol around lit stove is dangerous and
care must be take in handling aerosols.

The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regula�ons
Approved Document J. If installa�on is into an exis�ng chimney then it must be sound and have no cracks or other faults which
might allow fumes into the house. Older proper�es, especially, may have chimney faults or the cross sec�on may be too large .
Mendip Stoves recommend the use of a solid fuel flue lining system for all installa�on into exis�ng chimneys. All chimney
systems must be used in accordance with Building Regula�ons Approved Document J.
If an exis�ng chimney is used the chimney must be clear of obstruc�on and be swept clean immediately before installa�on of
the stove. The chimney should be tested to confirm the chimney will provide the correct chimney pressure for the stove. If the
stove is fi�ed in place of an open fire the chimney should be swept one month a�er installa�on to clear any soot falls which
may have occurred due to the difference in combus�on between the stove and the open fire. If there is no exis�ng chimney then
either a prefabricated block chimney in accordance with Building Regula�ons Approved Document J or a twin walled insulated
stainless steel flue to BS 1856-1 . These chimneys must be fi�ed in accordance with the manufacturer’s instruc�ons and Building
Regula�ons. A single wall metal flue pipe is suitable for connec�ng the stove to the chimney but is not suitable for using for the
complete chimney. The connec�ng flue pipe must have a minimum diameter of 125 mm and its dimension should be not less
than the size of the outlet socket of the stove. Registered smoke exempt models burning wood only can be installed on flue of
125mm throughout. Any bend in the chimney or connec�ng flue pipe should not exceed 45

. 90 degree bends should not be

used other than within 150 mm of stove rear flue outlet.

HEALTH AND SAFETY PRECAUTIONS

FLUE & CHIMNEY CONNECTION TO STOVE

Содержание Ashcott

Страница 1: ...TION MANUAL Wood burning Smoke Exempt Op onal Models Guide d u lisa on et Mode d Emploi ASHCOTT SE ASHCOTT PEDESTAL SE ASHCOTT LOGSTORE SE M00560 00 00 00 00 M00561 00 00 00 00 M00562 00 00 00 00 M005...

Страница 2: ...is appliance For further informa on on installing and using fireplaces and wood burning stoves please see the relevant building regula ons These instruc ons cover the basic principals to ensure the sa...

Страница 3: ...nd lit stove is dangerous and care must be take in handling aerosols The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regula ons Appro...

Страница 4: ...ed using a flexible brush Only Use a dry cloth on external surfaces Over me the glass may become dirty clean with a damp cloth and polish off with damp cloth If the stove has not been used for some me...

Страница 5: ...not be located where the heat dissipa ng through the walls of fireplaces or flues could ignite it Therefore when installing the stove in the presence of combus ble materials due account must be taken...

Страница 6: ...Stoves are fi ed internally with a formed vermiculite combus on chamber the panels that form the chamber are designed to ensure the maximum efficiency of the stove and are an integral part of the cle...

Страница 7: ...cquainted yourself with the controls of this appliance see page 9 The heat resistant paint on your stove will cure and harden the first me you light your appliance The curing process produces a good d...

Страница 8: ...l the fire is established 5 Once the fire bed is established slide air control to the middle posi on posi on for the stove to burn cleanly plenty of secondary air is needed do not be tempted to shut t...

Страница 9: ...including designa on and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements The ASHCOTT SE stove has been recommended as suitable for use in smoke c...

Страница 10: ...with current Building Regula ons the installer may have fi ed a permanent air supply vent into the room in which the stove is installed to provide combus on air This air vent should not under any circ...

Страница 11: ...being used e the door seals are in good condi on f the chimney dra may be too strong g check ash pan seal and h check for ash below ash pan causing pan to seat incorrectly and clean out 3 Soot forms...

Страница 12: ...rned fuel residues To enable a good flow of air through the appliance to reduce condensa on and subsequent damage leave the air controls fully open It is important that the flue connec on any applianc...

Страница 13: ...ovided when handling parts likely to be hot when the stove is in use Your stove has the following parts in the stove 1 Cast Iron grate log retainer 2 Ashpan 3 Stove Glove 4 Top plate decora ve cover p...

Страница 14: ...a travers cendrier et soulevez la grille en fonte Remove Baffle brick by li ing up brick and sliding forward then lt brick slightly to remove Re rez le deflecteur en levant le deflecteur et glisser ve...

Страница 15: ...on car la brique du c t sup rieur descend quand la brique est enlev e Upper side brick Brique laterale superieur Remove side right and side le front bricks Qui er les briques du cote droite et gauche...

Страница 16: ...16 OF 32 SPARE PARTS LIST LISTE DES PI CES D TACH ES...

Страница 17: ...60 20 06 99 00 REAR CONVECTION PANEL Panneaux convec on arri re 1 69 M10560 20 03 99 00 INNER CONVECTION PANEL Plaque de convec on 1 70 M10560 20 08 99 00 M6X30 HEX HD BOLT M6 x 30 Hex boulon 4 71 M10...

Страница 18: ...ntretoise en laiton 2 10 U91000 98 06 31 00 M6X12 HEX HEAD SCREW M6 x 12 Hex vis 4 11 U91000 98 07 31 00 M5X16 HEX SOCKET C SUNK SCREW M5X16 HEX PRISE t te frais e 2 12 U91002 00 00 31 00 M6 WASHER M6...

Страница 19: ...o maintain the air ght combus on chamber Then remove the leg reten on bolts to free the legs from the stove body Remove the levelling bolts from the stove leg which will later secure the pedestal logs...

Страница 20: ...t Il faut perme re au peinture de s cher et a rer la pi ce avant l allumage de l appareil Ciment r fractaire Certains types de ciments r fractaires sont caus ques et ne doivent pas entrer en contact a...

Страница 21: ...ne doivent pas tre u lis s autrement que dans les 150 mm de sor e de la chemin e de l arri re du po le Ces instruc ons concernent les principes fondamentaux de bonne installa on des po les mul combus...

Страница 22: ...on locales et aussi dans ce guide d u lisa on Si le po le doit tre install sur un plancher en bois il doit tre recouvert d un mat riau non combus ble et conform ment aux r gles de construc on locales...

Страница 23: ...nt lors du ravitaillement viter de jetez les b ches l impact par r des b ches peut causer des fissures pr matur es au niveau des panneaux de vermiculite Raccordement pour chemin e Les po les Mendip so...

Страница 24: ...N EST PAS UN INCINERAT UR MENDIP STOVES conseille l u lisa on d un THERMOSTAT de chemin e pour v rifier que votre po le ne surchauffe pas Me ez le THERMOSTAT DIRECTEMENT AU DESSUS DU POELE sur le con...

Страница 25: ...s allume feux placez les dans le po le et fermez la porte ce e posi on L espace permet l air suppl mentaire de d marrer le po le et r duit la condensa on sur la vitre 4 Une fois les flammes du bois bi...

Страница 26: ...et poussez la re e de control d air 75 ferm L u lisa on du po le d terminera les param tres qui vont g n rer les meilleurs r sultats U lisez un thermostat de fum e pour v rifier que le po le ne surch...

Страница 27: ...ez a que l entr e d air ne soit pas obstru e d aucune mani re b que le conduit des fum es et de la chemin e soient d gag s c l u lisa on d un combus ble adapt d l alimenta on suffisante en air de la p...

Страница 28: ...ne bonne circula on de l air travers l appareil pour r duire la condensa on et les dommages ult rieur laissez les contr les d air compl tement ouvert Il est important que la liaison du conduit de fum...

Страница 29: ...29 OF 32 L ENTRETIEN ANNUEL A A B C D E F G 2015 1186 kW ENERGIA ENERGIJA ENERGY ENERGIE A A A A A A Mendip Stoves Ltd Ashco 4 7 MP ASHCOTT ENERGY LABEL M10560 49 02 99 00 VERSION 1 0 JAN 2018...

Страница 30: ...30 OF 32...

Страница 31: ...31 OF 32...

Страница 32: ...mail info eurostove co uk Telephone 01934 750 500 Part of the Eurostove Group Distribu en France par la soci t Distributed in France and Benelux by Eurostove SAS Centre d Affaires Rue de L horlogerie...

Отзывы: