background image

2 OF 32

Contents

PAGE

ITEM

2 -12

Installa�on Instruc�ons

ENG

13 - 19

How to? Exploded parts diagrams

ENG

Pièces détachées, vue éclatées, assemblage

FRA

20 - 29

Guide d’u�lisa�on et Mode d'Emploi

FRA

30 - 31

Cer�ficate - EN Test

This appliance is guaranteed for 12 months subject to condi�ons. The extended warranty will only be valid if the annual
service plus flue sweeping has been carried out and noted on the warranty card and the appliance has been registered with
Mendip stoves .

Register online today to ac�vate warranty: online. h�p://www.mendipstoves.co.uk/SIT/StoveRegistra�on

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

ASHCOTT

ASHCOTT PEDESTAL

ASHCOTT LOGSTORE

This manual refers to the stoves listed above, which are tested in accordance with EN 13240.

Thank you for purchasing your new stove from Mendip Stoves. Please read this manual carefully to ensure that you get
maximum enjoyment and performance from your new stove and to prevent any poten�al opera�onal problems. Please note
that “all local regula�ons, including those referring to na�onal and European Standards, need to be complied with when
installing this appliance”. For further informa�on on installing and using fireplaces and wood burning stoves, please see the
relevant building regula�ons.
These instruc�ons cover the basic principals to ensure the sa�sfactory installa�on of your WOOD stove, although detail may
need slight modifica�on to suit par�cular local site condi�ons.

MODEL NAME

Height (mm)

Width (mm)

Depth (mm)

Weight

ASHCOTT

575

424

370

70 KG

ASHCOTT PEDESTAL

750

424

370

92 KG

ASHCOTT LOGSTORE

800

424

370

92 KG

IMPORTANT

These instruc�ons cover the basic principles to ensure the sa�sfactory installa�on of Mendip Stoves
product :- ASHCOTT, although detail may need slight modifica�on to suit par�cular local site condi�ons.
In all cases the installa�on must comply with current Building Regula�ons, Local Authority Byelaws and
other specifica�ons or regula�ons as they affect the installa�on of the stove. It should be noted that the
Building Regula�ons requirements may be met by adop�ng the relevant recommenda�ons given in Bri�sh
Standards BS 8303 Code of Practice for installa�on of domes�c hea�ng and cooking appliances burning
solid mineral fuel, BS EN 15287-1:2007 design, installa�on and commissioning of chimneys as an
alterna�ve means to achieve an equivalent level of performance to that obtained following the guidance
given in Approved Document J.

Содержание Ashcott

Страница 1: ...TION MANUAL Wood burning Smoke Exempt Op onal Models Guide d u lisa on et Mode d Emploi ASHCOTT SE ASHCOTT PEDESTAL SE ASHCOTT LOGSTORE SE M00560 00 00 00 00 M00561 00 00 00 00 M00562 00 00 00 00 M005...

Страница 2: ...is appliance For further informa on on installing and using fireplaces and wood burning stoves please see the relevant building regula ons These instruc ons cover the basic principals to ensure the sa...

Страница 3: ...nd lit stove is dangerous and care must be take in handling aerosols The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regula ons Appro...

Страница 4: ...ed using a flexible brush Only Use a dry cloth on external surfaces Over me the glass may become dirty clean with a damp cloth and polish off with damp cloth If the stove has not been used for some me...

Страница 5: ...not be located where the heat dissipa ng through the walls of fireplaces or flues could ignite it Therefore when installing the stove in the presence of combus ble materials due account must be taken...

Страница 6: ...Stoves are fi ed internally with a formed vermiculite combus on chamber the panels that form the chamber are designed to ensure the maximum efficiency of the stove and are an integral part of the cle...

Страница 7: ...cquainted yourself with the controls of this appliance see page 9 The heat resistant paint on your stove will cure and harden the first me you light your appliance The curing process produces a good d...

Страница 8: ...l the fire is established 5 Once the fire bed is established slide air control to the middle posi on posi on for the stove to burn cleanly plenty of secondary air is needed do not be tempted to shut t...

Страница 9: ...including designa on and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements The ASHCOTT SE stove has been recommended as suitable for use in smoke c...

Страница 10: ...with current Building Regula ons the installer may have fi ed a permanent air supply vent into the room in which the stove is installed to provide combus on air This air vent should not under any circ...

Страница 11: ...being used e the door seals are in good condi on f the chimney dra may be too strong g check ash pan seal and h check for ash below ash pan causing pan to seat incorrectly and clean out 3 Soot forms...

Страница 12: ...rned fuel residues To enable a good flow of air through the appliance to reduce condensa on and subsequent damage leave the air controls fully open It is important that the flue connec on any applianc...

Страница 13: ...ovided when handling parts likely to be hot when the stove is in use Your stove has the following parts in the stove 1 Cast Iron grate log retainer 2 Ashpan 3 Stove Glove 4 Top plate decora ve cover p...

Страница 14: ...a travers cendrier et soulevez la grille en fonte Remove Baffle brick by li ing up brick and sliding forward then lt brick slightly to remove Re rez le deflecteur en levant le deflecteur et glisser ve...

Страница 15: ...on car la brique du c t sup rieur descend quand la brique est enlev e Upper side brick Brique laterale superieur Remove side right and side le front bricks Qui er les briques du cote droite et gauche...

Страница 16: ...16 OF 32 SPARE PARTS LIST LISTE DES PI CES D TACH ES...

Страница 17: ...60 20 06 99 00 REAR CONVECTION PANEL Panneaux convec on arri re 1 69 M10560 20 03 99 00 INNER CONVECTION PANEL Plaque de convec on 1 70 M10560 20 08 99 00 M6X30 HEX HD BOLT M6 x 30 Hex boulon 4 71 M10...

Страница 18: ...ntretoise en laiton 2 10 U91000 98 06 31 00 M6X12 HEX HEAD SCREW M6 x 12 Hex vis 4 11 U91000 98 07 31 00 M5X16 HEX SOCKET C SUNK SCREW M5X16 HEX PRISE t te frais e 2 12 U91002 00 00 31 00 M6 WASHER M6...

Страница 19: ...o maintain the air ght combus on chamber Then remove the leg reten on bolts to free the legs from the stove body Remove the levelling bolts from the stove leg which will later secure the pedestal logs...

Страница 20: ...t Il faut perme re au peinture de s cher et a rer la pi ce avant l allumage de l appareil Ciment r fractaire Certains types de ciments r fractaires sont caus ques et ne doivent pas entrer en contact a...

Страница 21: ...ne doivent pas tre u lis s autrement que dans les 150 mm de sor e de la chemin e de l arri re du po le Ces instruc ons concernent les principes fondamentaux de bonne installa on des po les mul combus...

Страница 22: ...on locales et aussi dans ce guide d u lisa on Si le po le doit tre install sur un plancher en bois il doit tre recouvert d un mat riau non combus ble et conform ment aux r gles de construc on locales...

Страница 23: ...nt lors du ravitaillement viter de jetez les b ches l impact par r des b ches peut causer des fissures pr matur es au niveau des panneaux de vermiculite Raccordement pour chemin e Les po les Mendip so...

Страница 24: ...N EST PAS UN INCINERAT UR MENDIP STOVES conseille l u lisa on d un THERMOSTAT de chemin e pour v rifier que votre po le ne surchauffe pas Me ez le THERMOSTAT DIRECTEMENT AU DESSUS DU POELE sur le con...

Страница 25: ...s allume feux placez les dans le po le et fermez la porte ce e posi on L espace permet l air suppl mentaire de d marrer le po le et r duit la condensa on sur la vitre 4 Une fois les flammes du bois bi...

Страница 26: ...et poussez la re e de control d air 75 ferm L u lisa on du po le d terminera les param tres qui vont g n rer les meilleurs r sultats U lisez un thermostat de fum e pour v rifier que le po le ne surch...

Страница 27: ...ez a que l entr e d air ne soit pas obstru e d aucune mani re b que le conduit des fum es et de la chemin e soient d gag s c l u lisa on d un combus ble adapt d l alimenta on suffisante en air de la p...

Страница 28: ...ne bonne circula on de l air travers l appareil pour r duire la condensa on et les dommages ult rieur laissez les contr les d air compl tement ouvert Il est important que la liaison du conduit de fum...

Страница 29: ...29 OF 32 L ENTRETIEN ANNUEL A A B C D E F G 2015 1186 kW ENERGIA ENERGIJA ENERGY ENERGIE A A A A A A Mendip Stoves Ltd Ashco 4 7 MP ASHCOTT ENERGY LABEL M10560 49 02 99 00 VERSION 1 0 JAN 2018...

Страница 30: ...30 OF 32...

Страница 31: ...31 OF 32...

Страница 32: ...mail info eurostove co uk Telephone 01934 750 500 Part of the Eurostove Group Distribu en France par la soci t Distributed in France and Benelux by Eurostove SAS Centre d Affaires Rue de L horlogerie...

Отзывы: