![MEN 04M036N01 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/men/04m036n01/04m036n01_user-manual_1770465018.webp)
Input Conditioning
MEN Mikro Elektronik GmbH
18
3.2
Single-Ended Acquisition (Current/Voltage)
A standard M-Module version for 16 single-ended channels is available (see MEN’s
). The input voltage range is adjusted to ±10V for full scale and the second-
order lowpass filter limits the input frequencies to 1kHz (can be changed on
request).
The current measurement version has a 62.5-
Ω
shunt installed for full scale at
±20mA. The gain factor selected by software must be 8!
For each individual channel, space is provided for mounting discrete components,
such as resistors and trimmers, shunt resistors, voltage dividers or filter components.
Figure 1.
Block diagram of single-ended input
The following tables give the standard pin assignments for single-ended versions.
Table 2.
16 single-ended inputs: pin assignment of 25-Pin D-Sub receptacle connector
1
I0
14
I8
2
I1
15
I9
3
I2
16
I10
4
I3
17
I11
5
I4
18
I12
6
I5
19
I13
7
I6
20
I14
8
I7
21
I15
9
BI
22
TRIG
10
IGND
23
-
11
IGND
24
-
12
IGND
25
-
13
IGND
Buffer
Filter
Multiplexer
16
1
14
13
25