16
LEAK TESTING THE VALVES, HOSES, AND CONNECTIONS
1. Ensure all burners are “Off”.
2. Ensure the gas hose is connected to the gas source, and the shutoff valve is turned on.
3. Mix up a solution of 50% water and 50% liquid dish soap. Do not use any household cleaner
solution.
4. Spray or brush on the solution covering the following areas: gas hose connections to the shut-off
valve, gas hose, and the gas hose connection to the gas manifold assembly.
5. Growing bubbles on any of the parts and connections listed above indicate a gas leak. Immediately
shut off the natural gas using the shutoff valve. Retighten the connections or order replacement parts
as needed. Continue to test as necessary until no leaks are detected.
Grill Placement
Grill Operations
BEFORE AND AFTER LIGHTING
1. Ensure your grill is located on a level surface.
2. Lock the locking casters by pressing or turning the locking lever on the casters counterclockwise before
use. Unlock by turning or pressing the locking lever on the casters clockwise.
3. Keep the gas grill area clear and free from combustible materials, gasoline, and
other flammable vapors and liquids.
4. Ensure nothing is obstructing the flow of combustion and ventilation air.
5. Ensure the ventilation openings of the cylinder enclosure are free and clear of debris.
6. Visually check burner flames.
!
FOR YOUR SAFETY
1. Minimum clearance required from
sides and back of unit to adjacent
combustible construction is 24 inches
(61 cm).
2. Do not locate or use this outdoor
cooking gas appliance under
overhead combustible surfaces.
APARTMENT RESIDENTS
Check with your apartment manager regarding
your regulations for barbecues.
Do not face the grill directly into the wind
Keep any electrical supply cord and the fuel
supply hose away from any heated surfaces
and water.
WARNING
1.
DO NOT USE THE GRILL
if you cannot stop a leak.
2. Do not use any match or open flame, or smoke, during leak testing.
3. Do not light a burner during leak testing.
!
24"(61cm)
24"
(61
cm
)