![Mellanox Technologies SX1012 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/mellanox-technologies/sx1012/sx1012_user-manual_1768396038.webp)
Installation
Rev 1.4
41
Mellanox Technologies
Figure 26: Two Power Inlets - Electric Caution Notifications
CAUTION
Risk of electric shock and energy
hazard. The two power supply
units are independent.
Disconnect all power supplies to
ensure a powered down state
inside of the switch platform.
ACHTUNG
Gafahr des elektrischen
Schocks. Entferrnen des
Netzsteckers elnes Netz-
teils spannungsfrei. Um
alle Einhieten spannungs-
frei zu machen sind die
Netzstecker aller Netzteile
zu entfernen
ATTENTION
Risque de choc et de danger
e’lectriques. Le de’branch-
ment d’une seule alimentation
stabilise’e ne de’branch
uniquement qu’un module
“Alimentation Stabilise’e”.
Pour isoler completement le
module en cause, Il faut
de’brancher toutes les alimen-
tations stabilise’es.
2.9
System Bring-Up
2.9.1 Configuring Network Attributes
The procedures described in this chapter assume that you have already installed and powered-on
according to the instructions in this document.
To perform initial configuration of the system, perform the following:
Step 1.
Connect a host PC to the Console RJ45
port of the system using the supplied har-
ness cable (DB9 to RJ45). Make sure to connect to the Console RJ45 port and not to the
(Ethernet) MGT port.
Caution: After inserting a power cable and confirming the green System Status LED
light is on, make sure that the Fan Status LED shows green.
If the Fan Status LED is not green, unplug the power connection and check that the
fan module is inserted properly and that the mating connector of the fan unit is free of
any dirt and/or obstacles. If no obstacles were found and the problem persists, call
your Mellanox representative for assistance.
The bring-up procedures described in this section do not apply to managed systems.
Such systems are ready for operation after power-on.
Содержание SX1012
Страница 24: ...Installation Rev 1 4 27 Mellanox Technologies Figure 11 Installation Kit Parts for a Side by Side Installation...
Страница 35: ...Rev 1 4 38 Mellanox Technologies Figure 24 SFP Removal and Insertion Tool...
Страница 54: ...Interfaces Rev 1 4 57 Mellanox Technologies Figure 36 Pull out Tab...
Страница 76: ...Rev 1 4 111 Mellanox Technologies 5 6 45 C 113 F 8 3 7 8 9 10 11 12...
Страница 79: ...Rev 1 4 114 Mellanox Technologies 3 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 PSU InfiniBand...
Страница 92: ...Rev 1 4 127 Mellanox Technologies 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 InfiniBand...