Rev 1.2
Mellanox Technologies
47
5
Troubleshooting
5.1
Troubleshooting Instructions
Table 20 - Troubleshooting
Problem
Indicator
Symptoms
Corrective Measures
LEDs
System Status LED is
blinking for more than 5
minutes
This state means that the MLNX-OS software did not
boot properly and only firmware is running.
To overcome it, connect to the system via the console
port, and check the software status. You might need to
contact an FAE if the MLNX-OS software did not load
properly
System Status LED is Red
This state can indicate a number of problems:
•
Critical system fault (CPU error, bad firmware)
•
Over Temperature
To overcome it:
•
Check Environmental conditions (room temperature)
Fan Status LED is Red
This state is indicative of a problem with the FAN.
•
Check that the FAN is fully inserted and nothing blocks
the airflow.
•
Replace the FAN FRU if needed.
Front PSU Status LED is
Red
This state is indicative of a problem with the PSU.
•
Check/replace the power cable.
•
Replace the PSU if needed.
The activity LED does not
light up (InfiniBand):
Make sure that there is an SM running in the fabric.
Содержание SB7700
Страница 25: ...Rev 1 2 Mellanox Technologies 25 Figure 19 Locking Mechanism...
Страница 60: ...Rev 1 2 Mellanox Technologies 60 5 6 7 8 9 10...
Страница 61: ...Rev 1 2 Mellanox Technologies 61 11 12 13 14 15 16...
Страница 62: ...Rev 1 2 Mellanox Technologies 62 17 18 19 20 21 WEEE 22...
Страница 64: ...Rev 1 2 Mellanox Technologies 64 7 8 9 10 InfiniBand 11 12 13 PSU InfiniBand...
Страница 77: ...Rev 1 2 Mellanox Technologies 77 4 5 45 C 113 F 8 3 6 7 8 9 10 InfiniBand InfiniBand...
Страница 78: ...Rev 1 2 Mellanox Technologies 78 11 12 13 14 15 16 UL CSA UL CSA 3 16 AWG 1 5 6 4 5 125 13 HAR 3 1 0 300 250 10...