Mellanox MLNX-OS Switch Management
Password:
Installation
Rev 1.2
Mellanox Technologies
32
Step 3.
Login as admin (default username is
admin
, password
admin
).
Step 4.
Once you get the CLI prompt, you are ready to use the system.
For additional information about MLNX-OS, refer to MLNX-OS User Manual located on Mellanox sup-
port web.
2.8
FRU Replacements
2.8.1
Power Supply
Mellanox systems equipped with two replaceable power supply units work in a redundant config-
uration. Either unit may be extracted without bringing down the system.
Make sure that the power supply unit that you are NOT replacing is showing all green,
for both the power supply unit and System Status LEDs.
Power supply units have directional air flows similar to the fan module. The fan mod-
ule airflow must coincide with the airflow of all of the power supply units. If the power
supply unit airflow direction is different from the fan module airflow direction, the
system
’s
internal temperature will be affected.
For power supply unit air flow direction, refer to Section 2.2 on page 13.
To extract a power supply unit:
Step 1.
Remove the power cord from the power supply unit.
Step 2.
Grasping the handle with your hand, push the latch release with your thumb while pulling the
handle outward. As the power supply unit unseats, the power supply unit status LEDs will turn
off.
Step 3.
Remove the power supply unit.
Содержание SB7700
Страница 25: ...Rev 1 2 Mellanox Technologies 25 Figure 19 Locking Mechanism...
Страница 60: ...Rev 1 2 Mellanox Technologies 60 5 6 7 8 9 10...
Страница 61: ...Rev 1 2 Mellanox Technologies 61 11 12 13 14 15 16...
Страница 62: ...Rev 1 2 Mellanox Technologies 62 17 18 19 20 21 WEEE 22...
Страница 64: ...Rev 1 2 Mellanox Technologies 64 7 8 9 10 InfiniBand 11 12 13 PSU InfiniBand...
Страница 77: ...Rev 1 2 Mellanox Technologies 77 4 5 45 C 113 F 8 3 6 7 8 9 10 InfiniBand InfiniBand...
Страница 78: ...Rev 1 2 Mellanox Technologies 78 11 12 13 14 15 16 UL CSA UL CSA 3 16 AWG 1 5 6 4 5 125 13 HAR 3 1 0 300 250 10...