19U QSFP SDR/DDR/QDR InfiniBand Switch Platform User’s Manual
Rev 1.7
Mellanox Technologies
29
Figure 20: Multiple Power Inlets - Electric Caution Notification
1. As soon as a switch is plugged in, make sure that the green power LEDs on the PSUs are on.
2. Check the Status LEDs on all of the management modules and confirm that all of the LEDs
show status lights consistent with normal operation.
3. Check that none of the ATTN status LEDs on the spines are yellow.
4. Go around to the other side of the switch chassis and check the leaf board status LEDs.
Warning: Any yellow or red status LEDs on any of the management modules is
cause for concern and must be dealt with immediately.
CAUTION
Risk of electric shock and energy
hazard.
The PSUs are all independent.
Disconnect all power supplies to
ensure a powered down state
inside of the switch platform.
ACHTUNG
Gafahr des elektrischen
Schocks. Entferrnen des
Netzsteckers elnes Netz-
teils spannungsfrei. Um
alle Einhieten spannungs-
frei zu machen sind die
Netzstecker aller Netzteile
zu entfernen
ATTENTION
Risque de choc et de danger
e’lectriques. Le de’branch-
ment d’une seule alimentation
stabilise’e ne de’branch
uniquement qu’un module
“Alimentation Stabilise’e”.
Pour isoler completement le
module en cause, Il faut
de’brancher toutes les ali-
mentations stabilise’es.
DC
AC
OK
FAIL
OK
This LED should be off.
This LED should be on.
The yellow connector
LEDs should be blink-
ing.
The green connector
LEDs should be on.