Safety Warnings and LED Indications
Rev 1.7
Mellanox Technologies
18
2.2.4 Management Module LED Indicators
The switch system requires at least one management module.The management module has three
interfaces to connect to the MTS3610. They are:
• 1 RS232 “CONSOLE” connector
• 1 USB port
• 1 Ethernet “MGT”connector
There is also a Reset/Restore button. This button resets all of the leafs in the chassis by bringing
them down and powering them up when the button is pushed. When the button is held down for 15
seconds the chassis is reset and the factory defualt values for the configuration are implemented.
Figure 8: Management Module Status Indications
The management module LEDs display the switch system operating conditions.
Table 5 - LEDs Display for Normal Operation
LED
Description
Normal
State
STATUS
Off = No Power
Green = Unit is operating well- all temp. and voltages are OK.
Yellow = System warning. Attention needed (such as overheating).
Red = System not operational (Diagnostics fail, CPU hang,
HW fail, Overheat-critical)
Blinking Yellow=Restore factory defaults in progress.
Green
PS
off = No power
Green = operational
Red = PS fault detected. User should check individual power supplies for
fault indications.
Green
FAN SPINE
off = No power to fan
Green = operational
Red = Fault detected (fan broken, can't reach full RPMs)
Green
Содержание MTS3610D-6UNC
Страница 66: ...Rev 1 7 Mellanox Technologies 66...