REVISION 1.44.01 - 2 MAY 2018 

UI_0PTC04AAMLX 

Contact 

For the latest version of this document, go to our website at 

www.melexis.com. 

 
For additional information, please contact our Direct Sales team and get help for your specific needs: 

 

Europe, Africa 

Telephone: +32 13 67 04 95 

 

Email : [email protected] 

Americas 

Telephone: +1 603 223 2362 

 

Email : [email protected] 

Asia 

Email : [email protected] 

Disclaimer 

The information furnished by Melexis herein (“Information”) is believed to be correct and accurate. Melexis disclaims (i) any and all liability in connection with or arising out of the 
furnishing,  performance  or  use  of  the  technical  data  or  use  of  the  product(s)  as  described  herein  (“Product”)  (ii)  any  and  all  liability,  including  without  limitation,  special, 
consequential  or  incidental  damages,  and  (iii)  any  and  all  warranties,  express,  statutory,  implied,  or  by  description,  includ ing  warranties  of  fitness  for  particular  purpose,  non-
infringement and merchantability. No obligation or liability shall arise or flow out of Melexis’ rendering of technical or other services. 
The  Information  is  provided  "as  is”  and  Melexis  reserves  the  right  to  change  the  Information  at  any  time  and  without  notice.  Therefore,  before  placing  orders  and/or  prior  to 
designing the Product into a system, users or any third party should obtain the latest version of the relevant information to verify that the information being relied upon is current.   
Users  or  any  third  party  must  further  determine  the  suitability  of  the  Product  for  its  application,  including  the  level  of  reliability  required  and  determine  whether  it  is  fit  for  a 
particular purpose. 
The Information is proprietary and/or confidential information of Melexis and the use thereof or anything described by the Information does not grant, explicitly or implicitly, to 
any party any patent rights, licenses, or any other intellectual property rights.  
This document as well as the Product(s) may be subject to export control regulations. Please be aware that export might require a prior authorization from competent authorities.  
The Product(s) are intended for use in normal commercial applications. Unless otherwise agreed upon in writing, the Product(s ) are not designed, authorized or warranted to be 
suitable  in  applications  requiring  extended  temperature  range  and/or  unusual  environmental  requirements.  High  reliability  applications,  such  as medical  life-support  or  life-
sustaining equipment are specifically not recommended by Melexis.  
The Product(s) may not be used for  the following applications subject to export  control regulations: the development, product ion, processing, operation,  maintenance, storage, 
recognition  or  proliferation  of  1)  chemical,  biological  or  nuclear  weapons,  or  for  the  development,  production,  maintenance  or  storage  of  missiles  for  such  weapons:  2)  civil 
firearms, including spare parts or ammunition for such arms; 3) defense related products, or other material for military use  or for law enforcement; 4) any applications that, alone 
or in combination with other goods, substances or organisms could cause serious harm to persons or goods and that can be used  as a means of violence in an armed conflict or any 
similar violent situation.  
The  Products  sold  by  Melexis  are  subject  to  the  terms  and  conditions  as  specified  in  the  Terms  of  Sale,  which  can  be  found  at https://www.melexis.com/en/legal/terms-and-
conditions. 
 
 
This document supersedes and replaces all prior information regarding the Product(s) and/or previous versions of this document.  
 
Melexis NV © - No part of this document may be reproduced without the prior written consent of Melexis.  (2016) 

 

ISO/TS 16949 and ISO14001 Certified 

Содержание PTC-04

Страница 1: ...AAMLX User Manual Calibration Software PTC04 Programmer Introduction In this document you ll find a description of The Calibration Setup How to proceed with the calibration check What if the calibrati...

Страница 2: ...r 4 Calibration check 5 Before starting the calibration check 5 Manual voltmeter 8 The calibration check 9 There are three possible outcomes 9 What if the Calibration check failed 11 Check Calibration...

Страница 3: ...sion of the PTC04 has no impact on the quality of the PTC04 calibration it is advised to upload the ptc04_mlx90251_firmware hex or ptc04_mlx90316_firmware hex firmware to the PTC04 before replacing th...

Страница 4: ...VEN 7BITS OR PARITY NONE 8BITS TX TERM CR LANGUAGE SCPI LANGUAGE SCPI For configuration instructions please consult the user s manual of your multimeter All other settings are set by the software via...

Страница 5: ...and compare its results with the calibration parameters If the calibration parameters are out of tolerance they can be corrected Before starting the calibration check It is advised to leave the progra...

Страница 6: ...4 01 2 MAY 2018 UI_0PTC04AAMLX Figure 6 Calibration Check Press Verify Calibration to start the calibration You are reminded to leave your PTC04 powered up for minimum 30 to 60 minutes before starting...

Страница 7: ...With a manual voltmeter the program will start with calibrating the internal voltmeter which will be used to check the PTC04 programmer Figure 8 Proceed Check Press yes to continue At this stage the...

Страница 8: ...internal reference meter Press OK to continue For the calibration of the internal reference meter two series of 32 values are required Once the internal reference meter is calibrated the software wil...

Страница 9: ...At the end of the calibration check the program verifies if a correction of the calibration parameters is needed Figure 14 Calibration Check There are three possible outcomes 1 The program notifies yo...

Страница 10: ...04 If you press no there are no modifications done 3 At the end of the calibration the software verifies if the programmer was at temperature when the calibration started If the programmer was not at...

Страница 11: ...input of measured data If this occurs check the setup and redo the calibration check Very important If the calibration check is done with a manual voltmeter you have to take extra care that the measur...

Страница 12: ...a bad connection in the setup For example between the PTC04 main board and the calibration board When using a Keithley 2000 multimeter for the calibration the failure can also be caused by a wrong mea...

Страница 13: ...calibration parameters In the main window you get a list of the channels that have a large deviation from the default values Figure 23 List of channels that have a large deviation The large deviation...

Страница 14: ...s PTC04UI Calibration details How does the calibration work ADC In the graph below you have two curves the measurements of the ADC left Y axis and the reference measurements of the external voltmeter...

Страница 15: ...TC04 and the External Voltmeter which results in to correction parameters for offset and gain Graph 2 At the end of the calibration check these values of the ADC channels and the DAC are compared with...

Страница 16: ...d then the additional channels that are connected to that source Voltmeter on the PPS1 channel 0 and Channel 16 High sensitivity of the ADC PPS1 channel 0 of the DAC Current meter on the PPS1 channel...

Страница 17: ...Melexis and the use thereof or anything described by the Information does not grant explicitly or implicitly to any party any patent rights licenses or any other intellectual property rights This doc...

Отзывы: