MA-5195-ENG
PS20 NON STOP+ DRUM UNLOADER MANUAL
MELTER OPERATION
4-25
(*) Example values
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
40 °C
200 °C
10 °C
60 s
20 °C
60 s
230 °C
10 s
10 min
60 s
10 °C
20 °C
1.5 Heating Extra Settings
Programmable limits
min
max
Temperature warning (+/-)
Temperature alarm in zone (+/-)
Total alarm due to temperature
Pumping permission delay
Adaptative time
1.5 Extra temperature settings
• Pumping permission delay:
This is the time that the unit must wait to
activate pumping after all the active zones have reached a temperature
above [Set point temp. -3°].
• Programmable limits:
Two limits can be set to prevent set point
temperatures from being programmed above or below those values.
• Temperature warning:
A temperate (±°C/°F) and a time are defined to
indicate when the overheating or low temperature warning is activated in
each zone.
• Temperature alarm:
A temperature (±°C/°F) and a time are defined to
indicate when the overheating or low temperature alarm is activated in
each zone.
If either of those values are reached (±) and maintained for the set time,
the unit disconnects the heating in the zone causing the error. If the error
persists 3 minutes later, the remainder of the zones are automatically
disconnected. If the affected zones are the tank or the distributor, the unit
also stops the pumping.
• Alarma total por temperatura:
Se define un valor (+°C/°F) y un
tiempo que indican cuando se activa la alarma por sobretemperatura.
Si cualquier zona alcanza esta temperatura y permanece el tiempo
establecido, el equipo desconecta el calentamiento de todas las zonas y
detiene el bombeo.
• Adaptive time:
Automatic interval setting for warning and alarm
temperatures, when the user reprogrammes the setpoint values.
Status
Actual
temperature*
Set point
emperature*
Heating
Pumping
OUTPUTS
Temp.OK
zones
Alarm
Activated
Ready /
Running
150
150
ON
ON
ON
OFF
ON / OFF
140
150
ON
ON
ON
ON
ON / OFF
160
130
150
OFF
Unit
OFF when...
Error in Tank
Error in Distributor
OFF
ON
ON/OFF
170
OFF
Zone in error
ON when...
Error in the remainder
of the Zones
190
150
OFF
All Zones
OFF
OFF
ON
OFF
Содержание PS 20 NON STOP+
Страница 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Страница 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Страница 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Страница 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...