MELER GLUING SOLUTIONS
4-36
MELTER OPERATION
PISTÓN
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
6
2.2 Extra Settings
Regrind charger
Channel number
Feeder
Pattern controller
Level detector
Extermal HMI
Wireless communication
PISTÓN
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
START
Network Name
SSID:
0.0.0.0
IP:
Online
Wireless Communication
Channel number
Remote actuation
Remote SW update
Static Configuration
Connection Status
Wireless communication (Wi-Fi)
Optionally, the unit comes equipped with a wireless communication system to
connect to a local network. This system connects the unit to a Meler Services
Platform(*) with the following main functions:
• Monitoring.
Regularly sends the platform’s status and operating data.
The data can be configured according to user needs.
• Actions and Programming.
It is possible to send specific actions or chan-
ge the programming of a specific unit.
• Technical support.
The unit provides direct information on its status and
can schedule unit maintenance or keep a log of all interventions done on
it.
(*) Check with the After-Sales Service or your Meler Sales Agent for more
information about this service performance.
Connection configuration
1. Install the ‘Espressif Esptouch’ app on a smartphone device.
2. Connect the device to the local Wi-Fi network where you want to connect
the melter, then run the app.
3. On the melter’s screen, click START to start syncing. Follow the instruc-
tions on the app to configure the melter’s Wi-Fi access.
4. The unit’s screen will show the connection status, the name of the Wi-Fi
network, and the IP address automatically assigned.
You can also configure the following options from this screen:
• Remote control.
Enables the unit to be able to receive actions.
• Remote software update.
Enables the unit to be able to receive software
updates.
• Static configuration.
Enables the configuration of a static IP address for
the melter.
PISTÓN
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
6
2.2 Extra Settings
Regrind charger
Channel number
Feeder
Pattern controller
Level detector
Extermal HMI
Wireless communication
Содержание Micron PUR LC
Страница 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Страница 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Страница 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 49: ...MELTER OPERATION 4 15 MA 5184 ENG MICRON PUR LC MC ADHESIVE MELTER This page is intentionally left blank ...
Страница 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Страница 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...