![Meler Micron PUR LC Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/meler/micron-pur-lc/micron-pur-lc_instruction-manual_1767109062.webp)
MELER GLUING SOLUTIONS
4-28
MELTER OPERATION
ENGRANE
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
120 s
Charge
Charge
3. Charge
Level alarm
Sound on alarm
‘3. Load’ Menu
Esta pantalla permite controlar las diferentes cuestiones relativas a la carga
de adhesivo.
Screen 1: Minimum adhesive level sensor
• Level alarm:
Time after which the unit stops and activates a low-level
alarm.
• Sound with alarm:
Allows you to configure the sensor alarm to emit a
sound
Screen 2: Automatic adhesive feeder
ENGRANE
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
1 s
60 s
90 s
90 s
Charge
Charge
3. Charge
Automatic feeder alarm
Sound on alarm
Over charge time
Charge error alarm
Automatic charge
CHARGE
Cover opened alarm
• Automatic feeder:
Activates or deactivates automatic feeding
.
When you press
‘
CHARGE’, This lets you activate manual loading. When
pressed, it loads, and when released, the loading stops.
• Feeder alarm.
Defines the time that must pass to give an external feed
alarm.
• Overfill time:
This lets you configure for how much time the adhesive
will continue to be loaded once the lower level sensor has activated (tank
sufficiently full, but not completely full).
• Charge error alarm:
This defines the maximum amount of time for filling
the tank. If this time is exceeded, the unit displays an alarm.
• Open tank lid alarm:
An alarm sounds when the tank lid is open and it
stops loading immediately.
• Buzzer:
This lets you set whether or not loading alarms emit a sound.
ENGRANE
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
120 s
Charge
Charge
3. Charge
Level alarm
Sound on alarm
ENGRANE
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
15 s
120 s
Charge
Charge
3. Charge
Sound on alarm
INJECT
Auto. inject.
Cycle time
Injection time
Screen 3: Dry air/gas injection
• Automatic injection:
Activates or deactivates dry air/gas injection.
By pressing ‘INJECT’, you can activate and deactivate injecting manually.
• Cycle time:
Sets the time that has to elapse between dry air/gas
injections.
• Injection time:
Sets the dry air/gas injection time.
• Sound with alarm:
Allows you to configure the injection system alarms to
emit a sound.
Содержание Micron PUR LC
Страница 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Страница 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Страница 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 49: ...MELTER OPERATION 4 15 MA 5184 ENG MICRON PUR LC MC ADHESIVE MELTER This page is intentionally left blank ...
Страница 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Страница 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...