![Meler Micron PUR LC Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/meler/micron-pur-lc/micron-pur-lc_instruction-manual_1767109056.webp)
MELER GLUING SOLUTIONS
4-22
MELTER OPERATION
ENGRANE
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
Manual OFF
T: Tank
External OFF
D: Distributor
1.1: Hose 1
1.2: Applicator 1
2.1: Hose 2
2.2: Applicator 2
3.1: Hose 3
3.2: Applicator 3
4.1: Hose 4
4.2: Applicator 4
5.1: Hose 5
5.2: Applicator 5
6.1: Hose 6
6.2: Applicator 6
Signal 1
Group 1: Robot Arm RIGHT
ENGRANE
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
-20 °C
5 min
-10 °C
5 min
1.2 Sequential
Enable sequential
Define groups
Group B
Group C
ENGRANE
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
Sequential group A
T: Tank
D: Distributor
1.1: Hose 1
1.2: Applicator 1
2.1: Hose 2
2.2: Applicator 2
3.1: Hose 3
3.2: Applicator 3
4.1: Hose 4
4.2: Applicator 4
5.1: Hose 5
5.2: Applicator 5
6.1: Hose 6
6.2: Applicator 6
1.3 Inhibitions
This menu allows you to create seven groups of zones and program the mode
in which the Inhibition (Off) can be activated or disabled.
The following is indicated for each group:
• Name of the group.
The name can be changed to identify it more easily.
• Manual inhibition of the group (Manual Off).
Whether it is possible to ma-
nually activate or deactivate the inhibition in that group from the ‘SHORT-
CUTS’ menu.
Manual inhibition takes priority over external inhibition.
• Automatic inhibition with external signal (External Off).
Whether it is
possible to externally activate or deactivate the inhibition in that group.
You must indicate which of the seven possible external signals will per-
form this function.
One signal can never be enabled in two different groups.
• Selected zones.
A zone may be selected in more than one group or may
not be in any grou.
1.2 Sequential Heating
This lets you start heating the zones one after the other. This prevents a zone
from being active for a long time until the slowest zone heats up.
This function allows you to create three heating groups: A, B and C. Press
‘Define groups’ to go to a screen where zones can be added to the groups:
• Group A:
this always includes the Tank, which is the slowest and serves
as a reference for the remainder of the zones. Other zones can be added
so they begin to heat up with the Tank.
• Group B:
other zones can be added and some degrees of temperature
defined before the tank reaches its set point and a wait time.
• Group C:
the zones that are not in group A or B can be added here.
If a component in group B or C is deselected, it goes back to group A. By de-
fault, all the zones belong to group A.
Example:
- Tank set point temperature: 150°C
- Programming of Group B: -20°C / 5 minutes.
Group B begins to heat up 5 minutes after the tank reaches 130°C.
Содержание Micron PUR LC
Страница 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Страница 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Страница 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 49: ...MELTER OPERATION 4 15 MA 5184 ENG MICRON PUR LC MC ADHESIVE MELTER This page is intentionally left blank ...
Страница 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Страница 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...