![Meler Micron 5 Скачать руководство пользователя страница 99](http://html1.mh-extra.com/html/meler/micron-5/micron-5_instruction-manual_1767103099.webp)
TECHNICAL CHARACTERISTICS
7-5
MA-5079-ENG
MICRON GEAR ADHESIVE MELTER
Micron gear range option accessories
Automatic feeder system
Meler adhesive loaders ensure a continuous level of adhesive inside the tanks
of the melting units, eliminating the need for manual loading by the user.
Each time the tank sensor detects a low level of adhesive, it sends a signal to
the suction system, which transfers a load of pellets to the melting tank from
the adhesive container (or directly from the bag it comes in).
Air drying system for reactives adhesives
Polyurethane-based reactive adhesives, require a completely dry environment
before they can be applied, since when they come in contact with atmospheric
humidity, they reticulate, hardening quickly.
The Micron gear melting equipment ensures a dry environment thanks to the
addition of an air-drying system to these models, which provides a high level
of dehumidification. This guarantees that the adhesive is preserved without
premature reticulations inside the applicator unit.
Pneumatic by-pass valve pressure control system
The equipment’s by-pass valve provides an important safety feature, as it
limits the maximum pressure in the system, especially during continuous
pumping periods with closed applicators.
This valve may be a manual adjustment valve, using a threaded screw, or
with pneumatic control, using a pressure regulator and a pressure gauge. In
the latter case, the adhesive circuit pressure has a 1:13 ratio to the hydraulic
pressure.
Level control system
There are three methods for controlling the hot-melt level in the interior of the
tank: by means of a capacitive sensor that issues a warning when the adhesive
reaches the programmed level thanks to a low level signal, by means of a float
sensor with a low level display on the control board, or from the main machine
by means of a NO (normally open) voltage-free contact.
Warning light option
The warning light must be requested separately. There is a choice of the low
level and colourless (white) indicator light or the low level and temperature OK
indicator light (green). They are both the same for all machines.
Содержание Micron 5
Страница 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Страница 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Страница 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Страница 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...