![Meler Micron 5 Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/meler/micron-5/micron-5_instruction-manual_1767103089.webp)
MA-5079-ENG
MICRON GEAR ADHESIVE MELTER
6-9
TROUBLESHOOTING
Micron with 1 geared motor
Note
Hose 1
Hose 2
Hose 3
Hose 4
Hose 5
Hose 6
(1)
CN9 / M1
CN9 / M2
CN10 / M3
CN10 / M4
CN11 / M5
CN11 / M6
(2)
F04
F05
F06
F07
F08
F09
(3)
CN9 / M1 / DL3
CN9 / M2 / DL5
CN10 / M3 / DL7 CN10 / M4 / DL9 CN11/ M5 /DL11 CN11/ M6 /DL13
(4)
DL3
DL5
DL7
DL9
DL11
DL13
(5)
CN2
CN3
CN4
CN5
CN6
CN7
Causes
Checking
Comments
Actions
Hose damaged.
Replace the hose by
another one that works.
Change hose channel.
Change hose.
Pins and wiring
damaged.
Check voltage between
board and hose-output
connector (with the hose
plugged).
CN
(*)
connector (black wire-neutral
and blue wire-hose M
(*)
)
( 1 )
Change connectors.
Ribbon cable wrong
placed.
Observe ribbon cable
connection.
Ribbon cable correct if red LED light
on (DL15).
Put ribbon cable correctly.
Power board fuse
damaged.
Verify fuse continuity.
( 2 )
Check continuity with the unit
turned off.
Change fuse.
Power board
damaged.
Check voltage at the board
output (with the hose
plugged).
CN
(*)
board connector (black wire-
neutral and blue wire-hose M
(*)
).
Fuse shows continuity. DL
(*)
LED
light remains on.
( 3 )
Change power board.
Hose
Hose does not heat
Causes
Checking
Comments
Actions
Power board
damaged.
Check power board.
DL
(*)
LED green indicator is
continuously off.
( 4 )
Change power board.
Control board
damaged.
--
DL
(*)
LED green indicator is
continuously on.
( 4 )
Change control board.
Hose does not stop heating
Causes
Checking
Comments
Actions
Hose temperature
sensor malfunction.
Replace the hose by
another one that works.
Change hose channel.
Change hose.
Sensor wiring.
Check sensor board and
hose connector.
CN
(*)
sensor board connector
(black and green wire).
( 5 )
Change connector.
Sensor board
malfunction.
Last failure option.
Check first sensors, connections
and wirings.
Change the sensor board.
Temperature fluctuations in hose
Содержание Micron 5
Страница 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Страница 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Страница 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Страница 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...