Alarm displays
The melter equipments tell the user when a malfunction has occurred in
the unit, sending warning messages that may be seen on the control panel
display.
When an alarm appears, the control unit takes a series of steps to protect the
unit. Simply correct that malfunction and the control unit will reactivate the
equipment functions.
Code
Source
Actions
Heating
Pump
Main machine signal
Err 0
tank broken sensor
only tank off
off
off
One pump ins
tall
ed
Err 1
hose1 broken sensor
only hose1 off
off
off
Err 2
applicator1 broken sensor
only applicator1 off
off
off
Err 3
hose2 broken sensor
only hose2 off
off
off
Err 4
applicator2 broken sensor
only applicator2 off
off
off
Err 5
hose3 broken sensor
only hose3 off
off
off
Err 6
applicator3 broken sensor
only applicator3 off
off
off
Err 7
hose4 broken sensor
only hose4 off
off
off
Err 8
applicator4 broken sensor
only applicator4 off
off
off
Err 9
hose5 broken sensor
only hose5 off
off
off
Err 10
applicator5 broken sensor
only applicator5 off
off
off
Err 11
hose6 broken sensor
only hose6 off
off
off
Err 12
applicator6 broken sensor
only applicator 6 off
off
off
Err 13
distributor broken sensor
only distributor off
off
off
Err 100
tank overheating
all components off
off
off
Err 101
hose1 overheating
all components off
off
off
Err 102
applicator1 overheating
all components off
off
off
Err 103
hose2 overheating
all components off
off
off
Err 104
applicator2 overheating
all components off
off
off
Err 105
hose3 overheating
all components off
off
off
Err 106
applicator3 overheating
all components off
off
off
Err 107
hose4 overheating
all components off
off
off
Err 108
applicator4 overheating
all components off
off
off
Err 109
hose5 overheating
all components off
off
off
Err 110
applicator5 overheating
all components off
off
off
Err 111
hose6 overheating
all components off
off
off
Err 112
applicator6 overheating
all components off
off
off
Err 113
distributor overheating
all components off
off
off
Содержание Micron 5
Страница 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Страница 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Страница 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Страница 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...