![Meler Macro Series Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/meler/macro-series/macro-series_instruction-manual_1767094056.webp)
FOCKE MELER GLUING SOLUTIONS
4-24
MELTER OPERATION
000 to MAXIMUM RPM; press the right arrow key to go to the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 3 XXX
,
which means that the input voltage value is being programmed for point 3;
with the up/down arrow keys the value may be modified, within a range from
00.0 to 10.0 (to one decimal place); press the right arrow key to go to the next
point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 3 XXX,
which means that the output speed value is being programmed for point 3;
with the up/down arrow keys the value may be modified, within a range from
000 to MAXIMUM RPM; press the right arrow key to go to the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 4 XXX,
which means that the input voltage value is being programmed for point 4;
with the up/down arrow keys the value may be modified, within a range from
00.0 to 10.0 (to one decimal place); press the right arrow key to go to the next
point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 4 XXX,
which means that the output speed value is being programmed for point 4;
with the up/down arrow keys the value may be modified, within a range from
000 to MAXIMUM RPM; press the right arrow key to go to the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 5 100,
NOT EDITABLE; press the right arrow key to go to the following message:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 5 XXX,
which means that the speed value is being programmed for point 5; with the
up/down arrow keys the value may be modified, within a range from 000 to
MAXIMUM RPM; press the right arrow key to exit the menu.
Press the right arrow key to return to the menu, and the initial message is
displayed: The IN LED to the position
ON
and the OUT LED to the position
ON,
1 000.
To exit this menu, the equipment must be turned off and started up using the
control card ON/OFF button.
To save the newly entered data, use the right and left arrow keys to go forward
or backward in the menu: if any field has been modified using the up/down
arrow keys, and the ON/ OFF button is pressed to turn the equipment off, the
data will not be saved.
Current Vin voltage display
Whenever the Vin key is held pressed, the three digits on the right will show
the input voltage reading to one decimal point.
If the values for any point in the speed ramp table is being edited, and the Vin
key is held pressed for 3 seconds, the voltage value which is operating at this
time it will be copied to that value on the table.
By-pass valve regulation
The pumping system using a geared pump provides a constant flow of
adhesive, according to the pump’s rotational speed.
In this type of system, the pressure generated by the pump is the result of the
retentions found on the circuit (the length and diameter of the hose, elbows
6.0
6.0
Содержание Macro Series
Страница 1: ...MA 5052 ENG 221220 GLUING SOLUTIONS ADHESIVE MELTER MACRO SERIES INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 16: ...FOCKE MELER GLUING SOLUTIONS 2 4 INTRODUCTION Main components 10 10 12 14 13 11 15 1 2 3 7 6 8 9 4 5 5 ...
Страница 32: ...FOCKE MELER GLUING SOLUTIONS 3 12 INSTALLATION This page is intentionally left blank ...
Страница 58: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 6 4 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 71: ...ELECTRICAL DRAWINGS 7 1 MA 5052 ENG MACRO SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...