![Meler Macro Series Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/meler/macro-series/macro-series_instruction-manual_1767094054.webp)
FOCKE MELER GLUING SOLUTIONS
4-22
MELTER OPERATION
Minimum rpm alarm
This alarm will be triggered when the motor rotates at a speed that is below
the MINIMUM RPM ALARM for the period established in the MINIMUM RPM
ALARM TIME field.
• When this alarm is triggered, an ‘E.L.’ error is shown on the control
card.
• To reset this error, you must turn off and start up the control card with
its ON/OFF button.
Variator alarm
This alarm is triggered when the control card input is activated by a variator
error signal.
• When this alarm is triggered, an ‘E.U.’ error is shown on the control
card.
• The error message will be maintained while the variator error input
(E5) remains active. As soon as this input is deactivated the alarm will
be reset.
Note:
In the event that a RPM alarm and a variator ERROR alarm should
coincide, alternating messages will appear on the display.
Configuring speed ramp
For equipment operating in external reference, the display will show the
current pump rotation set point (input reference conversion as per the full
scale and the conversion table).
The conversion table may be programmed with up to 5 points (input voltage (V)
and output speed (RPM)).
By default the table is programmed (0 V = 0 rpm and 10 V = 100 rpm):
Содержание Macro Series
Страница 1: ...MA 5052 ENG 221220 GLUING SOLUTIONS ADHESIVE MELTER MACRO SERIES INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 16: ...FOCKE MELER GLUING SOLUTIONS 2 4 INTRODUCTION Main components 10 10 12 14 13 11 15 1 2 3 7 6 8 9 4 5 5 ...
Страница 32: ...FOCKE MELER GLUING SOLUTIONS 3 12 INSTALLATION This page is intentionally left blank ...
Страница 58: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 6 4 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 71: ...ELECTRICAL DRAWINGS 7 1 MA 5052 ENG MACRO SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...