4-21
MELTER OPERATION
MA-5052-ENG
MACRO SERIES MELTER MANUAL
User configuration menu
To open this menu, press simultaneously the left arrow key, the right arrow
key, and ON/OFF button of the pump control card.
If the security password is enabled, the security password must be entered
to access this menu. By default, all the equipments is set to 000 that the user
may change at any time. If the security password is not enabled, direct access
will be given to the following menu:
1. MAXIMUM RPM ALARM:
this will be a value set between 0 and the value
programmed in the MAXIMUM RPM field. If we do not wish this alarm to be
operational it must be programmed to the MAXIMUM RPM value. The default
value is 100 (consequently, alarm not operational).
2. MAXIMUM RPM ALARM TIME:
this will be a period programmed between
0 and 999 (in seconds). In the event that the output RPM exceed the value
programmed for MAXIMUM RPM ALARM during the period established in this
field, MAXIMUM RPM error will be activated (the pump will stop, and an error
message will be displayed). By default, this value is 30 seconds.
3. MINIMUM RPM ALARM:
this will be a value set between 0 and the value
programmed in the MAXIMUM RPM field. This value may never be greater
than the value programmed in the MAXIMUM RPM ALARM field. If the value
programmed is ‘0’ the error function will be disabled. By default, this value is 0
(disabled).
4. MINIMUM RPM ALARM TIME
: this will be a period programmed between
0 and 999 (in seconds). In the event that the output RPM are less than the
programmed value for MINIMUM RPM ALARM during the period established
in this field, MINIMUM RPM error will be activated (the pump will stop, and an
error message will be displayed). By default, this value is 30 seconds.
5. PUMPING SAFETY FUNCTION:
this consists of an editable field (0 enabled –
1 disabled). By default, this is set to ‘0’ (enabled).
6. SECURITY PASSWORD:
The security password may be changed in an editable
field. The current password must be entered to access and edit the field. (See
the section ‘Password security’ in this chapter).
7. ENABLING THE SECURITY PASSWORD:
this consists of an editable field (0
disabled, 1 enabled). The current password must be entered to access and edit
the field. By default, this is set to ‘0’. (See the section ‘Password security’ in this
chapter).
Displaying alarms and reset function
Maximum rpm alarm
This alarm will be triggered when the motor rotates at a speed exceeding the
MAXIMUM RPM ALARM value for the period established in the MAXIMUM RPM
ALARM TIME field.
• When this alarm is triggered, an ‘E.H.’ error is shown on the control
card.
• To reset this error, you must turn off and start up the control card with
its ON/OFF button.
Содержание Macro Series
Страница 1: ...MA 5052 ENG 221220 GLUING SOLUTIONS ADHESIVE MELTER MACRO SERIES INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 16: ...FOCKE MELER GLUING SOLUTIONS 2 4 INTRODUCTION Main components 10 10 12 14 13 11 15 1 2 3 7 6 8 9 4 5 5 ...
Страница 32: ...FOCKE MELER GLUING SOLUTIONS 3 12 INSTALLATION This page is intentionally left blank ...
Страница 58: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 6 4 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 71: ...ELECTRICAL DRAWINGS 7 1 MA 5052 ENG MACRO SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...